Laserfiche WebLink
a I D <br /> i <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F:RE, shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2 Lots shall be graded to comply with R401.3 of the F:B.C. <br /> . <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require.a R.O:W.use permit. All 4 sides.of driveway thra the sidewalk shall have <br /> expansion material.. <br /> 6: 'All setbacks shall be nnet. <br /> 7. All property markers shall be uncovered-and marked at time:of first inspection. <br /> 8: All A.D.A. requirements shall be met: . <br /> 9. No electric,plumbing; mechanical, or framing shall be covered without an inspection and <br /> approval first: <br /> 10: All Garages shall comply with section R302:6 of the F.B-C. (Fire Separation): <br /> 11. Appliances_shall.not be installed in a location where subject to mechanical damage unless = <br /> .. <br /> proteeted.by approved barriers. M303:4 of the F.B.0 <br /> comply . <br /> 12.-Water heaters shall.coin 1 with section P607.3 of the:F:B:C: <br /> 13. Foundation supports for A/C uriits.shall be-raised at least 3" above finished grade.-M1308:1 - <br /> 14: Return air in all bedrooms: F.B.C. Ml620:4 <br /> 1.5. Smoke detectors.are to be installed in accordance with_R313:1 of the_ .F.B.C. <br /> 16.All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 17. All means.of egress are to be in accordance with R311 of the F.B.C.. <br /> 18. "Green gypsum,board" shall not be used as a backer in showers or tubs. R702:4:2 F;B.C. . <br /> low Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating. <br /> or appliances or an attached garage. They shall lie installed in accordance with the F.B.C. <br /> 21. All,plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground.plumbing and:electric. <br /> 21 All 2016 N.E.C. Codes will be enforced: <br />