Laserfiche WebLink
21 Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. I! accordance with the Land Developinent Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25:.R403.5.3Hot water.pipe insulation <br /> Insulation for hot.Water.'pipe with'a minimum thermal resistance (R-value) of R-3 shall be applied-to the <br /> following:; <br /> Piping.31, inch (19.1 mm)and larger.in.nominal diameter: <br /> Piping.serving more than one dwelling unit. <br /> Piping located outside'the conditioned space:. <br /> Piping from the:water heater to a distribution mbri foid., <br /> Piping.located under a floor slab: <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower:door test shall be provided Before C.O: <br /> 26. A copy of the enemy cacls shall be with permit at all tithes. <br /> 27.. Copy of Fnalinsulation report shall be provided ivith permit before f1naL <br /> 28.-No fence, pool onscreen enclosure :is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> RB.C-.Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric.Code(2016). <br />