Laserfiche WebLink
139 M . P. H . WIND ZONE <br /> THIS STRUCTURE HAS BEEN DESIGNED AS AN ENCLOSED STRUCTURE IN ACCORDANCE WITH SECTION 1609 OF THE FLORIDA <br /> BUILDING CODE 6th EDITION (2017). STRUCTURES LOCATED IN A DEBRIS BORN AREA REQUIRES IMPACT GLASS OR SHUTTERS. <br /> ALL EXTERIOR WINDOWS AND GLASS DOORS ARE REQUIRED TO BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br /> 101/IS2 STANDARD AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE <br /> CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br /> COMPONENTS AND CLADDING WIND LOADS FOR BUILDINGS WITH A MEAN ROOF HEIGHT OF 30 FEET. <br /> WIND EXPOSURE B <br /> RISK CATEGORY il <br /> INTERNAL PRESSURE CDEF.(GCPI) 0.18(ENCLOSED) <br /> WIND SPEED�V u" 139 MPH(3 SEC GUST) <br /> WIND SPEED Va5d 108 MPH <br /> EXPOSURE ADJUSTMENT FACTOR 1.00 <br /> ROOF SLOPE: 0-27 DEGREES MEAN ROOF HEIGHT: 30' AREA A IS 4 FT MINIMUM <br /> SQFT ROOF COMPONENTS WALL COMPONENTS <br /> ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 <br /> 10 12.2/49 12.2/-33 12.2/-49 21.2/-22 21.2/-28 <br /> 20 11.1/-18 11.1/-31 11.1/-46 20.2/-22 20.2/-26 <br /> so 10/-18 10/-27 10/-42 19/-20 19/-23 <br /> 100 10/-17 10/-24 10/-39 18/-19 18/-22 <br /> r_-7070 15.8/-17 15.8/-17 <br /> ,Cffy&,f <br />