<br /> Sections from the Code
<br /> Product Approval Method Method 1 Option D
<br /> Date Submitted 04/10/2020
<br /> Date Validated 04/10/2020
<br /> Date Pending FBC Approval 04/13/2020
<br /> Date Approved 06/02/2020
<br /> Date Revised 08/13/2020
<br /> Summary of Products
<br /> Go to Page 2 ; 0 mil Page 3/30 0
<br /> FL# Model,Number or Name Description
<br /> 16107AI 41 W6-09 DSIU-117171:9200,9201, Double-skin Insulated PUR(exterior skin 27 ga.min.;Interior
<br /> 9203 HDP20,HDPF20,HDPL20, skin 27 ga.min.)Single-Car(up to 9'0"wide)WINDCODEO
<br /> 7200,7201,7203,8200,8201,8203 W6 Garage Door with Optional Impact-Reslstant Lites
<br /> Limits of Use Installation Instructions
<br /> Approved for use In HVHZ:Yes PL16107 R11 11 104184-A-Rev02-sJgnedp_df
<br /> Approved for use outside HVHZ:Yes Verified By:Scott Hamilton FL PE 63286
<br /> Impact Resistant;Yes Created by Independent Third Party:No
<br /> Design Pressure:+38 PSF/-44 PSF Evaluation Reports
<br /> Other.Max.Wind Speed(V_ult):170 MPH.Solid doors or FL16107 R11 AE CBPC 140220-A.12df
<br /> doors with optional Impact-resistant glazing are Impact- Created by Independent Third Party:No
<br /> resistant(large missile Impact).
<br /> 16107.42 42 W6-09 DSIU-IF171:9200,9202, Double-skin Insulated PUR(exterior skin 27 ga.min.;Interior
<br /> 9203,HDP20,HDPF20,HDPL20, skin 27 ga.min.)Single-Car(up to 9'0"wide)WINDCODEQ)
<br /> 17200,7201,7203,8200,-8201,8203 W6 Garage Door
<br /> Limits of Use Installation Instructions
<br /> Approved for use In HVHZ:No FL16107 R11 jr 104184-B-Rev02-sjgDg&Wj
<br /> Approved for use outside HVHZ:Yer. Verified By:Scott Hamilton FL PE 63286
<br /> Impact Resistant.No Created by Independent Third Party:No
<br /> Design Pressure.+38 PSF/-44 PSF Evaluation Reports
<br /> Other.Doors with standard glazing meet the wind load FL16107 R11 AE CBPC 140220nA.i2df
<br /> requirements of the building code but DO NOT meet the Impact Created by Independent Third Party:No
<br /> resistant requirement for windbome debris regions.
<br /> 6107.43 43 W6-16 DSIU-11`171:9200,9201, Double-skin Insulated PUR(exterior skin 27 ga.min.;Interior
<br /> 9203,HDP20,HDPF20,HDPL20, skin 27 ga.min.)Double-Car(9'2"to 16120 wide)WINDCODE@
<br /> 7200,7201,7203,8200,8201,8203 W6 Garage Door with Optional impact-Resistant Utes
<br /> Limits of Use Installation Instructions
<br /> Approved for use in HVHZ:Yes FL16107 R11 IT 104879-A-RevQ3-sign%LVd
<br /> Approved for use outside HVHZ:Yes Verified By:Scott Hamilton FL PE 63286
<br /> Impact Resistant,Yes Created by Independent Third Party:No
<br /> Design Pressure:+38 PSF/-42 PSF Evaluation Reports
<br /> Other:Max.Wind Speed(V_ult):170 MPH.Solid doors or FL16107 R11 AE CBPC 140220-A.Ddf
<br /> doors with optional Impact-resistant glazing are Impact- Created by Independent Third Party:No
<br /> resistant(large missile Impact). I
<br /> 16107.44 4 W6-16 DSIU-1F171*9200,9201, Double-skin Insulated PUR(exterior skin 27 ga.min.;Interior
<br /> 920:3HDP20,HDPF20,HDPL20, skin 27 ga.min.)Double-Car(97'to 16'2"wide)WINDCODE@
<br /> 00,
<br /> 172 7201,7203,8200,8201,8203 W6 Garage Door
<br /> Limits of Use Installation Instructions
<br /> Approved for use in HVHZ:No FL16107 R11 11 104879-B-Rev03-sjgned.Qff
<br /> Approved for use outside HVHZ,.Yes Verified By:Scott Hamilton FL PE 63286
<br /> Impact Resistant:No Created by Independent Third Party:No
<br /> Design Pressure:+38 PSF/-42 PSF Evaluation Reports
<br /> Other.Doors with standard glazing meet the wind load FL16107 R11 AE CBPC 140220-A.od
<br /> requirements of the building code but DO NOT meet the Impact Created by Independent Third Party:No
<br /> resistant requirement for windbome debris regions.
<br /> I
<br /> 16107.45 45 W3-09 DSIU-2A171*,9130,9131, Double-skin Insulated PUR(exterior skin 27 ga.min.;Interior
<br /> 9133,HOP13,KDPF13,HDPL13, skin 27 ga.min.)Single-Car(up to 9'0'wide)WINDCODE0
<br /> 17130,7131,7133,8130,8131,8133 W3 Garage Door
<br /> Limits of Use Installation Instructions
<br /> Approved for use In HVHZ:No FL16107 1111 It 104175Rev02TsigMqdj2df
<br /> Approved for use outside HVHZ,.Yes Verified By:Scott Hamilton FL PE 63286
<br /> Impact Resistant,No Created by Independent Third Party:No
<br /> Design Pressure:+20 PSF/-21 PSF Evaluation Reports
<br /> Other-The OPTIONAL glazing available for this product meets FL16107 R11 Ag CBPC 140220-A.12
<br /> the wind load requirements of the building code but DOES NOT Created by Independent Third Party:No
<br /> meet the Impact resistant requirement for windborne debris
<br /> regions.The product without glazing DOES comply with the
<br /> impact resistant requirement for windbome debris regions(ref
<br /> 1609.1.2 FBC).
<br />
|