Laserfiche WebLink
/ Single Phase Inverter <br /> with HD-Wave Techn®l®gy for North America <br /> SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-U.S/ <br /> SE760OH-US / SE1000OH-US / SE1140OH-US <br /> SE300OH-US811 00O .00O .11 1111 40O <br /> OUTPUT <br /> Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 1600 10000 114DO @ 240V VA <br /> 3300 @ 208V I 5000 @ 208V 10000 @ 208V <br /> 3800 @ 240V 6000 @ 240V 1 11400 @ 240V <br /> Maximum AC Power Output 3000 3300 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA <br /> AC Output Voltage Min.-Nom.-Max V <br /> (211-240-264) Vac <br /> AC Output Voltage Min.-Nom.-Marc. Vac <br /> (183-208-229) <br /> AC Frequency(Nominal) 59.3-60-60.511- Hz <br /> Maximum Continuous Output 12.5 16 21 I 25 32 42 47.5 A <br /> Current @240V <br /> Maximum Continuous Output - 16 - 24 - i 48.5- A <br /> Current @208V <br /> GFDI Threshold 1 A <br /> Utility Monitoring,Islanding Protection, Yes <br /> Country Configurable Thresholds <br /> INPUT <br /> Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W <br /> Maximum DC Power @208V - 5100 7750 15500 W <br /> Transformer-less,Ungrounded Yes <br /> Maximum Input Voltage 480 Vdc <br /> Nominal DC Input Voltage 380 400 Vdc <br /> Maximum Input Current @240VII) 8.5 10.5 13.5 16.5 20 27 30.5 I Adc <br /> Maximum Input Current @208VIa - I 9 13.5 27 Adc <br /> Max.Input Short Circuit Current 45 Adc <br /> Reverse-Polarity Protection Yes <br /> Ground-Fault Isolation Detection 50042 Sensitivity <br /> Maximum Inverter Efficiency 99 99.2 % <br /> CEC Weighted Efficiency gg 99_@240V <br /> 98.5 @ 208V <br /> Nighttime Power Consumption <2.5 W <br /> ADDITIONAL FEATURES <br /> Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) <br /> Revenue Grade Data,ANSI C12.20 Optional"[ <br /> Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect <br /> STANDARD COMPLIANCE <br /> Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 <br /> Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) <br /> Emissions FCC Part 15 Class B <br /> INSTALLATION SPECIFICATIONS <br /> AC Output Conduit Size/AWG Range 1'Maximum/14-6 AWG 1'Maximum/14-4 AWG <br /> DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1°Maximum/1-3 strings/14-6 AWG <br /> AWG Range <br /> Dimensions with Safety Switch 17 7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ <br /> (HxWxD) mm <br /> Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg <br /> Noise <25 <50 dBA <br /> Cooling Natural Convection <br /> Operating Temperature Range -13 to+140/-25 to 6011(-40'F/-40°C option)Isl 'F/-C <br /> Protection Rating NEMA 4X(Inverter with Safety Switch) <br /> °i For other regional settings please contact SolarEdge support <br /> A higher current source may be used,the inverter will limit its input current to the values stated <br /> Revenue grade inverter P/N.SExmxH-US000NNC2 <br /> "For power de-rating information refer to:https.//,w ..solaredge com/sites/detault/files/se-temperature-derating-note-na.pdf <br /> -40 version P/N SExxxxH-US000NNU4 <br /> '0 SolarEdge Technologies.Inc All rights reserved SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SalarEdge Technologies,Inc.All ®®� <br /> other trademarks mentioned herein are trademarks of their respective owners.Date:032019/`/Ol/ENG NAM.Subject to change w R without notice. <br />