My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-726
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-726
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2022 1:44:14 PM
Creation date
2/24/2022 11:18:31 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-726
Building Department - Name
ZENON,EFRAIN & ISABELLE
Address
7130 BOXER ROUND PL
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:398475A4-9752-4AD3-BBF7-AA6C43DDOAF4 <br /> Wind Uplift <br /> Simplified Procedure for Components and Cladding <br /> ASCE 7-10,Section 30.5 <br /> V= 145 mph Basic Wind Speed <br /> Exposure D ASCE 7-10,Section 26.7 <br /> = 1.47 Adjustment Factor for building height,ASCE 7-10,Figure 30.5-1 <br /> Kit= 1 Topographic Factor,ASCE 7-10,Section 26.8.2 <br /> Roof 0= 27.0 deg <br /> sanchor= 48 in Horizontal spacing of roof anchors <br /> Attib= 22.31 sf Panel Area tributary to,each roof anchor <br /> r <br /> Pnet30 Net Wind Design Pressure,ASCE 7-10,Figure 30.5-1 <br /> Roof Zone Zone 1 Zone 2 Zone 3 As shown in ASCE 7-10,Figure 30.5-1 <br /> 31.5 psf 49.1 psf 89.3 psf <br /> Pnet=AK41?net3o= Design Wind Uplift Pressure,ASCE 7-10,Equation 30.5-1 <br /> Zone 1 Zone 2 Zone 3 <br /> 46 psf 72 psf 131 psf <br /> Pnet= 16 psf Minimum Design Wind Pressure,ASCE 7-10, Section 30.2.2 <br /> Use 46 psf Use 72 psf Use 131 psf <br /> Connection to Existing Roof Framing <br /> F.S.= 1 Additional Factor of Safety applied to withdrawal force,if desired <br /> DLpanei= 3.00 psf <br /> Zone 1 Zone 2 Zone 3 <br /> Wuplift= 46 psf 72 psf 131 psf <br /> Abib= 22.3 sq.ft 11.2 sq.ft 5.6 sq.ft <br /> Pig=F.S.x Attih x(0.613-0.6W) Withdrawal force for each roof anchor <br /> Zone 1 Zone 2 Zone 3 <br /> -578.7lbs -231.51bs -107.3lbs <br /> Connection Capacity <br /> db= 5/16 in Lag Screw diameter <br /> Dpen= ' 2.50 in Lag Screw penetration into existing framing member <br /> Southern Pine Species of wood framing <br /> CD= 1.6 Load Duration Factor;for Wind Loading,NDS Table 2.3.2 <br /> Ct= 0.7 Temperature Factor,NDS Table 10.3.4 <br /> W= 235 lb/in Withdrawal Capacity NDS Equation 12.2-1 <br /> W'=CD x Ct x W= 263 lb/in Adjusted withdrawal value <br /> Pattow=Dpen x W,= 657 lbs Based on penetration depth <br /> Zone 1 Zone 2 Zone 3 <br /> DEMAND= 579 lbs 231 lbs 107 lbs <br /> Max Load=0.881 OK <br /> CAPACITY= 6571bs 657 lbs 657 lbs <br /> _ r <br /> Page 3of3 vivi n , o2- <br />
The URL can be used to link to this page
Your browser does not support the video tag.