Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 Of the.2016 N.E.0 <br /> 24. In accordance with the-Land Development Code,lots.shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hof Water pipe insulation <br /> Insulation for_hot.Water pipe with a minimum thermal-resistance (R-value) of R-3 shall.be applied to the <br /> followin <br /> Piping:V.inch (19.1_mm)and larger in:nominal diameter.: <br /> Piping serving more than one dwelling unit: <br /> Piping located outside the conditioned space: <br /> Piping from the.Water heater to a:distribution manifold:. <br /> Piping.located under a floor slab: <br /> Buried in piping. <br /> Supply and return piping in recirculation'systems other than demand recirculation systems. <br /> 25:-Blower door test shall be provided,before C.O. <br /> 26.A copy of the enemu cacls shall be:ivith permit at all times <br /> 97.'Cone offinal insutation Yeyort-shall be provided with permit before r1nab <br /> 28.No fence,pool or screen enclosure :is issued with:thispermit <br /> F.F.E.-Finished Floor Elevation <br /> RB.C-.Florida Building Code 6th Edition . <br /> R.O.W.-Right of Way <br /> A.D.A.-.Americans.with Disabilities Act N.E.C.-National Electric,Code(2016) . <br />