Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> 24. 1.n accordance with the Land Development Code,lots.shall be sodded before_ final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water pipe insulation. <br /> Insulation for hot:water pipe Withh-a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: -- <br /> Piping-1.inch (19.1 mm)and larger in nominal diameter: <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping from the-water heater to a distribution manifold:. <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation'systems. <br /> 25: Blower door test shall be provided before C.O: <br /> 26 A copy ofthe energy cacls shall be with permit at all times <br /> 27. Copy of final.insulation report shall be provided with permit before flh A <br /> 28.No fence. pool onscreen enclosure Is issued with:this permit <br /> F.E.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R:O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities:Act N.E.C.-National Electric Code (2016) <br />