Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E., <br /> 24. In accordance with the Land Development Code, lots shall.be sodded before final at least.10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water.pipe insulation. <br /> Insulation for hot,water pipe with a minimum thermal resistance (R-value) of R-3 shall.be applied to the <br /> following:. <br /> :. <br /> Piping V.inch (19.1 mm)and larger in nominal diameter. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping from the water heater to a'distribution manifold. <br /> Piping:located under a floor slab: <br /> Buried in piping.. <br /> 'Supply and return piping in recirculation systems other than demand recirculation systems: <br /> 25.Blower.door-test shall be provided,before* C.o: <br /> 26.A cony of the enerzy:cacls shall be with yern:it at all.times <br /> 27. Copv of tial insulation:Mort shall be provided with permit before final <br /> 8 2 . N o fence,cool or screen enclosure .rs issued with.this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code Oh Edition <br /> R.O.W.-Right of Way <br /> A.D:A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) , <br />