Laserfiche WebLink
23. Tamper=Resistant.Receptacles in accordance with 406.11 ofthe:2016 N.E:C <br /> 24. In accordance with the.Land Development Code,lots shall.be sodded before final at least 10_ <br /> feet around the structure. <br /> 25.-.R403.5.3Hot water.pipe insulation. <br /> r InsulatioFi fo hot.water pipe with'a minimum thermal resistance.(R-value)of;R-3 shall.tie applied-to the- <br /> following: <br /> Piping:4.inch (1.9.1.mm)and larger.in.nominal diameter: <br /> Piping_serving more-than:one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping from the Water heater to a'distribution manifold.. . <br /> Piping.located under,a floor slab: <br /> Buried in piping, <br /> Supply and return piping in recirculation'systems other than demand recirculation systems: <br /> 25.Blower:door test shall'lbe provided Before C.O: <br /> 26.A copy of the energy cacls shafl be:with permit at all times <br /> 27 COnV of Mal insulation report shall be provided with Dermifbefore final <br /> 28. No fenee,-pool or screen enclosure :is issued ivith:this-permit. <br /> F.F.E:-Finished Floor Elevation . <br /> F.B.C-Florida Building,Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act: N.E.C.-National Electric.Code(2016) <br />