Laserfiche WebLink
21 Tamper-Resistant Receptacles in accordance with 406.11 ofthe..2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots.shall be sodded before final at least 10 <br /> feet around the structure: <br /> 25:.R403.5.3Hot water pipe insulation <br /> Ansulation for hot.water.'pipe with a minimum thermal resistance (R-value) of-R-3 shallbe applied to the <br /> following: . . . <br /> Piping 3i:inch (19:1 mm)and larger in.:nominal.diameter. <br /> Piping,serving more than one dwelling unit: <br /> Piping located outside the conditioned space: <br /> Piping from the:waterheater to a:distribution manifold:. <br /> PiPing:located under a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation'systems other than demand recirculation systems. <br /> 25. Blower.door test shall be provided Before C-.O: <br /> 26. A copy of the enerzy:cacls shall be:with permit at all times <br /> 27 Copy of final ins ulation-Yetiort shall be provided with permit before Tnah <br /> 28. No fence, pool or screen enclosure :is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.G.Florida Building Code 6th Edition' <br /> 'R.-O.W.-Right of Way. <br /> A.D:A.=Americans with Disabilities Act : N.E.C.-National Electric Code(2016) . <br />