Laserfiche WebLink
1 • <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F RE, shall be a ininimum of 8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require.a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall bo met. <br /> 1: All.property markers shall be uncovered.and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met. <br /> 9; No electric,plumbing,in or framing shall be:covered without an inspection.and <br /> approval first. <br /> 10: Alt Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances sh I not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the E.B.C. <br /> 11 Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313:1 of the F.B.C. <br /> 16. A11 glazing requirements are to be in accordance-with R308.4 of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum.board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monokide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. Thoy shall,be installed in accordance with the F.B.C: <br /> 21. All plumbing,in6chanical, and electrical shall he separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />