My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-775
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-775
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2022 1:51:21 PM
Creation date
2/27/2022 1:23:06 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-775
Building Department - Name
SANTOS,IDALIA
Address
39352 LINCOLN AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r i <br /> Enphase IQ 7 and IQ 7+ Microinverters <br /> INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US" <br /> Commonly used module pairings' - 235 W-.350 W+i 235 W-440 W+ <br /> Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules <br /> Maximum input DC voltage 48 V '60 V - <br /> Peakpowertrackingvoltage 27V-37V - 27V-45V <br /> Operating range 16 V 48 V 16 V 60 V <br /> Min/Max start voltage 22 V/48 V 22 V/60 V <br /> ,---- <br /> Max DC short circuit current(module Isc) 15 A - 15 A <br /> - ----------------- - -- <br /> Overvoltage class DC port II II <br /> DC port backfeed current 0 A q. 0 A <br /> PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; <br /> AC side protection requires max 20A per branch circuit <br /> OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+.Microinverter <br /> Peak output power 250 VA 295 VA <br /> Maximum continuous output power 240 VA 290 VA <br /> Nominal(L-L)voltage/range, 240 V%: 208 V-/-. 240 V 208 V/ - - - J-- -- <br /> 211-264 V 183-229 V 211-264 V 183-229 V <br /> Maximum continuous output current 1.0 A(246 V) 1.15 A(208 V) 1.21FA(240 V) 1.39 A(208 V) <br /> Nominal frequency 60 Hz 60 Hz <br /> Extended frequency range 47-68 Hz 47-68 Hz _- <br /> AC short circuit fault current over 3 cycles 5.8 Arms <br /> Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) <br /> - <br /> Overvoltage class AC port <br /> AC port backfeed current 0 A 0 A <br /> 'Power factor setting 1.0 1.0 -- <br /> Power factor(adjustable) 0.7 leading...0.71agging 0.7 leading...0.7 lagging <br /> EFFICIENCY @240 V @208 V @240.V @208 V <br /> Peak CEC efficiency 97.6% 97.6% 97.5% 97.3 <br /> CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% <br /> MECHANICAL DATA <br /> Ambient temperature range -400C to+65°C <br /> Relative humidity range 4%to 100%(condensing) <br /> Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q DCC 5 adapter) <br /> Connector type(IQ7-60-B-US&IQ7PLUS-72-13-US) Friends PV2(MC4 intermateable). <br /> Adaptors for modules with MC4 or UTX connectors: <br /> PV2 to MC4:order ECA-S20-S22 <br /> PV2 to UTX:order ECA-S20-S25 <br /> m x 302 mm. <br /> (without.liracket) <br /> - - - -> - <br /> Dimensions WxHxD m .212 mm x 175 <br /> Weight 1.08 kg(2.38 Ibs)1 <br /> Cooling Natural convection-No fans <br /> Approved for wet locations Yes <br /> Pollution degree PD3 <br /> Enclosure Class II double-insulated,corrosion resistant polymeric enclosure <br /> Environmental category/UV exposure rating NEMA Type 6%outdoor. - -- <br /> FEATURES <br /> Communication Power Line Communication(PLC) <br /> Monitoring Enlighten Manager and MyEnlighten monitoring options. <br /> Both options require installation of an Enphase IQ Envoy. <br /> Disconnecting means The AC and DC conneciors have been evaluated and approved by UL for use as the load fireak _ <br /> disconnect required by NEC 690. <br /> Compliance CA Rule 21 (UL 1741-SA) <br /> UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, <br /> CAN/CSA-C22.2 NO.107.1-01 <br /> This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and <br /> NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for <br /> and DC conductors,when installed according manufacturer's instructions. <br /> 1.No enforced DC/AC ratio.See the compatibility calculator at httl2s*Henphase.com/en-us/c_unnort/module-compatibility. <br /> 2.Nominal voltage range can be extended beyond nominal if required by the utility. <br /> 3.Limits may vary.Referto local requirements to define the number of microinverters per branch in your area. <br /> To learn more about Enphase offerings,visit enphase.com v E N P H ASE. <br /> ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. <br /> 2018-05-24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.