Laserfiche WebLink
o � <br /> Snow Load 31-40 psf <br /> Modules In Landscape <br /> Wind Speed Exposure 2,12 c Roof Pitch.<6:12 7:12 c Roof Pitch.<12:12. <br /> ASCE 7705 ASCE 7-10' CategoryZone 4 Zone 2 Zone 3 Zone 1. Zone'2 Zone 3 <br /> B '59 <br /> 85 mph 110 mph C 67 42 <br /> D 56 35 <br /> B 54. <br /> 90 mph 115 mph C 61 38 <br /> D 51 32 <br /> B 45. <br /> 100 mph 125 mph C 51 32 <br /> D 74: 43 27 <br /> B 57 36 <br /> 110 mph 140-mph C 70 i 41 '26- <br /> D 59! 34 22 46 46 <br /> B 50 all <br /> 120 mph 150 mph ' C 61 '36 1 22' 47 . 47 <br /> D 51-: 30 19 49: 40 40 <br /> Notes: <br /> .Spacing Governed by Snow Load <br /> 1.)Values In above table represent the-maximum allowable spacing in Inches for pullout forces only on EcoFasten Solar standoff. <br /> however the designer-must round down.to meet appropriate ratter spacing <br /> 2.).Maximum allowed spacing approved by EccFasten Solar Is 72" <br /> 3.)Maximum allowed-standoff copcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module width of 40" <br /> 6.)Based on Msk Category II(ASCE 7-10)structures less than 30 feet in.height <br /> 7.)All adjustment factors are set to 1.No site specific engineering Is included In this table <br /> Snow-Load 31-40 psf <br /> i <br /> Wlnd Speed Exposure 2:12.c Roof Pitch e.6:12 7.12 c Roof•Pitch <br /> ASCE 7-05 ASCE 7-10 Category Zone.1 Zone 2 Zone 3 zone.-4 Zone 2 . Zone 3 <br /> 85 mph 110 mph C 3& 24" <br /> - D. _..32 _20-.. <br /> B 49. 30 <br /> 90 mph 115 mph C. 35 22 <br /> D 29 18 <br /> 100 mph 125 mph C 29 18 <br /> B 33 20. <br /> 110 mph 140 mph C 40 23 14 <br /> D 34 19 .12 26 26. <br /> 8•_.__._ 49 28 �8 <br /> 120_mph 150 mph C 35 20 12 <br /> D 29 17 10 28 <br /> Notes: <br /> -Spacing Governed by Snow Load <br /> 1.)-Values in above table represent the maximum allowable spacing In Inches for pullout forces only.on EcoFasten Solar standoff <br /> '2.)Maximum allowed spacing approved by EcoFasten Solar Is 48" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag pullo t capacity <br /> 5:)Values based on a maximum module length of 70" 11 <br /> 6.).Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering Is Included In.this table <br /> www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 M <br />