20-776
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-776
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2022 1:52:17 PM
Creation date
2/27/2022 1:24:06 PM
Metadata
Fields
Template:
Building Department
Company Name
CITY OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
20-776
Building Department - Name
CITY OF ZEPHYRHILLS
Address
38122 HENRY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
August 11,2020 <br /> 190-ft Self-Supporting Tower Structural Analysis Report CCI BU No 826548 <br /> TEP Project Number 48167.359855, Order 485515, Revision 4 Page 5 <br /> 3)ANALYSIS PROCEDURE <br /> Table 3- Documents Provided <br /> Document i Remarks Reference Source <br /> Geotechnical Report Nodarse &Associates, Inc. 3497292 CCISites <br /> Tower Foundation Drawings Valmont Microflect 3497291 CCISites <br /> Tower Manufacturer Drawings Valmont Microflect 3675014 CCISites <br /> Tower Reinforcement Drawings Tower Engineering Professionals 3946359 CCISites <br /> Post-Modification Inspection Tower Engineering Professionals 4460699 CCISites <br /> 3.1) Analysis Method <br /> tnxTower (version 8.0.7.4), a commercially available analysis software package, was used to create a <br /> three-dimensional model of the tower and calculate member stresses for various loading cases. <br /> Selected output from the analysis is included in Appendix A. When applicable, Crown Castle has <br /> calculated and provided the effective area for panel antennas using approved methods following the <br /> intent of the TIA-222 Standard. <br /> 3.2) Assumptions <br /> 1) The tower and structures were maintained in accordance with the TIA-222 Standard. <br /> 2) The configuration of antennas, transmission cables, mounts and other appurtenances are as <br /> specified in Tables 1 and 2, and the referenced drawings. <br /> 3) The following material grades were assumed: <br /> a) Tower Legs:ASTM A53-1346 <br /> b) Tower Bracing:ASTM A36 <br /> c) Anchor Rods:ASTM A615-75 <br /> 4) TEP assumed the soil properties for the bottom layer of caisson from 40-ft to 42-ft to match the <br /> properties of the soil later. <br /> This analysis may be affected if any assumptions are not valid or have been made in error. Tower <br /> Engineering Professionals should be notified to determine the effect on the structural integrity of the <br /> tower. <br /> 4) ANALYSIS RESULTS <br /> Table 4- Section Capacity(Summary) <br /> Section. Elevation(ft) Component Type Size Critical P(lb) ; epl (lb) % Pass/Fail <br /> No. Element' Capacity, <br /> T1 190-180 Leg Pipe 2.5 STD I -7843 56559 13.9 Pass <br /> T2 180-160 Leg PIPE 3.5 STD 21 -47246 101716 46.4 Pass <br /> T3 160-140 Leg Pipe 5 STD 51 -104970 165270 63.5 Pass <br /> T4 140-120 Leg Pipe 8 STD 75 -171821 347310 49.5 Pass <br /> T5 120-113.333 Leg Pipe 8 STD 99 -194002 347310 55.9 Pass <br /> T6 113.333- Leg Pipe 8 STD 111 -216504 P47310 62.3 Pass <br /> 106.667 <br /> T7 106.667-100 1 Leg Pipe 8 STD 120 -237436 347310 68.4 Pass <br /> T8 100-80 Leg Pipe 10 STD(SCH40) 129 -298116 484378 61.5 Pass <br /> T9 80-70 Leg Pipe 10 STD(SCH40) 147 -331189 484378 68.4 Pass <br /> T10 70-60 Leg Pipe 10 STD(SCH40) 159 -363965 484378 75.1 Pass <br /> T11 60-40 Leg Pipe 12 STD 168 -430732 602433 71.5 Pass <br /> tnxTower Report-version 8.0.7.4 <br />