PGT Industries,Inc. <br /> NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED <br /> A. DRAWINGS <br /> 1. Manufacturer's die drawings and sections, <br /> (Submitted tinder NOA No.15-0903.11) <br /> 2. Drawing No. MD-HR5410-01 titled "Horizontal Roller-NI", sheets 1 through 15 of <br /> 15, dated 05115115, with revision B dated 03/27/17, prepared by manufacturer, signed <br /> and sealed by Anthony Lynn Miller,P.E. <br /> B. TESTS <br /> 1. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94 <br /> 2)Large Missile Impact Test per FBC,TAS 201-94 <br /> 3)Cyclic Wind Pressure Loading per FBC, TAS 203-94 <br /> along with marked-up drawings and installation diagram of a PVC sliding glass door, <br /> a PVC fixed window and an aluminum sliding glass door, using: Kodispace 4SG TPS <br /> spacer system,Durascalo'spacer system, Super Spacero NXTIm spacer system and XL <br /> EdgeTNI spacer system at insulated glass,prepared by Fenestration Testing Laboratory, <br /> Inc., Test Reports No, FTL-8717, FTL-8968 and FTL-8970, dated 11116115, <br /> 06/07/16 and 06/02/16 respectively, all signed* and sealed by Idalmis Ortega, P.E. <br /> (Submitted tinder previous NOA No. 16-0714.18) <br /> 2. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 <br /> 2)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 <br /> 3)Water Resistance Test,per FBC,TAS 202-94 <br /> 4)Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94 <br /> 5)Large Missile Impact Test per FBC,TAS 201-94 <br /> 6)Cyclic Wind Pressure Loading per FBC, TAS 203-94 <br /> along with marked-up drawings and installation diagram of series 5410 and series <br /> 5510 PVC horizontal sliding windows,prepared by Fenestration Testing Laboratory, <br /> Inc.,Test Report No.FTL-8072, dated 02/03/15,signed and sealed by Idalmis Ortega, <br /> P.E. <br /> (Submitted tinder NOA No. 15-0903.11) <br /> C. CALCULATIONS <br /> 1. Anchor verification calculations and structural analysis, complying with FBC-S'h <br /> Edition (2014)dated 08/28/15,prepared by manufacturer, signed and sealed by <br /> Anthony Lynn Miller,P.E. <br /> (Submitted under NOA No. 15-0903.11) <br /> 2. Glazing complies with ASTM E1300-09 <br /> D. QUALITY ASSURANCE <br /> 1. Miami-Dade Department of Regulatory and Economic Resources (RER). <br /> Jorge M.Plasencia,P.E. <br /> Product Control Unit-Supervisor <br /> NOA No. 17-0411.09 <br /> Expiration Date: September 24,2020 <br /> Approval Date. August 31,2017 <br />