Laserfiche WebLink
fi. <br /> 23. Tamper Resistant Receptacles in accordance with 406.i 1 of the-2016 N.-E:C <br /> 24. In amordan6e with the Land Development Code, lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> Insulation for hot water pipe-with a minimum thermal resistance (R-value) of R-3 sl all.be applied to the <br /> !. <br /> following: <br /> Piping-3/: inch (1.9.1 mm) and larger in nominal diameter.; <br /> Piping serving more than:one dwelling unit: <br /> Piping located outside the conditioned space- <br /> Piping from the water heater to a distribution manifold., . <br /> Piping located under a floor slab. <br /> Buried in piping.' <br /> Supply and return piping in recirculation,!systems other than demand'recirculation systems. <br /> 25. Blower.door test shall be provided.before C.O; <br /> 26. A copy of the ener-or eacls shall be with permit at all times <br /> 27. Copy of final.insulation report shalhbe provided with permit before fnaL <br /> 28. No fence,pool or screen Enclosure :is issued with ihis.yermix <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C=.Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A. Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br /> i <br /> i <br /> i <br /> I <br />