Laserfiche WebLink
23.Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land_ Development Code,lots shall.be sodded before final at least 10 <br /> feet around-the structure. <br /> 25:.R403.5.3Hot water pipe insulation. <br /> insulation for hot water. pipe with.a minimum thermal resistance (R-value) of R-3 shall.be applied to the <br /> following: <br /> Piping�1a inch (19:1 mm)and larger in:nominal diameter. <br /> Piping serving more than one dwelling:unit: <br /> Piping located outside the conditioned space: <br /> Piping from the:wat&heater-to.a'distribution manifold.. <br /> -Piping located under.a floor slab: <br /> Buried in-piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25: Blower door-test shall be provided before C.O; <br /> 26. A copy of the energy cacls shall be with permit at all times: <br /> g7. Co&of final'insulation report shaft Abe provided with permit before flnaf <br /> 28. No fenee,pool or screen enclosure :is issued withahis permit` <br /> F.F.E.-Finished Floor Elevation . <br /> F.B.C- Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way.. <br /> A.D.A.=Americans with Disabilities Act N.E.C.--National Electric Code(2016) <br />