My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-814
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-814
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2022 1:53:56 PM
Creation date
2/27/2022 1:53:53 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-814
Building Department - Name
MEDINA,CHRIS & HEIDI
Address
6921 OAKCREST WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rom' REVISIONS: REVISED BY: DATE: <br /> MODEL DESIGNATION: Simonton Double Hung Series 75-75/75-09/07-75/ NO P.E.SEAL REQUIRED I: <br /> 07-09/07-10/07-20 Vinyl Window INSTALLATION SUPPORTED 10 UPDATED SIZES PER NEW TESTING. T.D.D. 01/29/14 <br /> MAXIMUM OVERALL NOMINAL SIZE: See Size Chart 2X BUCK BY AAMA TEST REPORTS 11 ADDED MIN.EDGE DISTANCE NOTES GIM 06/16/1S <br /> 12 ADDED NEW SIZE TO CHART LMH 07/10/15 <br /> DESIGN PRESSURE RATING: See Size Chart SILICONE CAULK 13 ADDED NOTES 12 B 13-MMA SOD LMn OB/IB/lfi <br /> SEE NOTES 13&14 14 UPDATED SIZES PER NEW TESTING. LMH 04/11/18 <br /> USABLE CONFIGURATIONS: X SILICONE CAULK <br /> X SEE NOTES 13&14 <br /> _GENERAL DESCRIPTION: The head,sill,and side jambs are extruded PVC.The wall 1 1/2°MIN.EMBED. —I <br /> thickness through which the anchor screw penetrates Is a 1�4"MAX.-SHIM - <br /> SILICONE CAULK <br /> minimum of 0.070". SEE NOTES 13&14 <br /> Q2X BUCK <br /> < SIZE CHART 1/4"MAX.SHIM <br /> OVERALL SIZE #B X 2 1/2"MIN. <br /> DP RATING <br /> l0 WIDTH HEIGHT 1 HEAD <br /> WOOD SCREW <br /> "w^ 01 1 <br /> 48" 60" t25 PSF <br /> 53" 74" *30 PSF 3/4"MIN.EDGE DIST. <br /> Q 48" 80" <br /> 52" 71" t35 PSF <br /> SILICONE CAULK <br /> 53" 80" t40 PSF SILCONE CAULK <br /> SEE NOTES 13&14 SEE NOTES 13&14 <br /> 36" 63" <br /> I-- 36" 74" t50 PSF SILICONE CAULK <br /> = 36" 72" 355 PSF SEE NOTES 13&14 <br /> Ur 1 JAMB <br /> w1,.3 <br /> 2X BUCK <br /> UI , �11 SILL <br /> F <br /> Q NOTES: <br /> 2_ 1.This Installation has been evaluated for use in locations adhering to the Florida Building Codes and where pressure requirements as determined <br /> by ASCE 7 Minimum Design Loads for Buildings and Other Structures do-not exceed the design pressure ratings herein,for use outside the <br /> —3 H.V.H.Z. <br /> 2.All exterior perimeter surfaces of the window must be caulked. Interior caulking is optional unless noted otherwise. <br /> U-I 3.Anchors shall be as specified and spaced as shown.Anchor embedment to base material shall be beyond wall dressing or stucco and into wood. <br /> O4.The responsibility for selection of Simonton products to meet any applicable local laws,building codes,ordinances,or other safety requirements <br /> rests solely with the architect,building owner,or contractor. <br /> X S.Shims are optional.Max.shim stack is 1/4". <br /> 6.Wood bucks(by others)must be engineered and anchored properly to transfer loads to the structure. <br /> X7. When used in areas requiring Impact protection this product REQUIRES the use of approved impact resistant shutters or other external <br /> = protection. <br /> 8. Flashing should be applied using the ASTM E 2112 method appropriate for the opening Into which the window Is being installed. <br /> 9.Installation screws must be at least 3/4"from the edge of the wood. <br /> 10. Installation screws may be placed in the Interior or exterior track of the jamb.Screws should be flush with the vinyl. <br /> 11.This product complies with ASTM E 1300. <br /> tj 12, Designation"X"and"O"stand for the following: X: Operable Panel-O: Fixed Panel. <br /> 13. Use 100%pure silicone caulk compliant with AAMA 800 Section 1-Sealant Specifications for use with Architectural Fenestration Products. <br /> For more details visit Simonton.com. <br /> 14.Use a backer rod on all joints>3/4"deep and/or wider than 1/4". Finished caulk joint should be a minimum of 3/8"deep. <br /> 4 <br /> X MATERIAL �/�l11 S12 DRAWIN O.: R <br /> "W" MAX. OVERALL FRAME WIDTH— ¢ DopertyURE STATEMENTmontonWin RMSFINISH: SIMONTON' B tNo113 la <br /> This document Is the property of Simonton Windows,which retains a0 Dimensional Tolerances rU 6 N By: DATE; <br /> proprietary and other rights to Its subject matter.This document Is Unless Olherwlse Specified w I " p 0 w s <br /> ALLOY 8 TEMPER: T.D.D. 03/02/07 <br /> provided to the recipient on the expressed condition that It Is not to be 1 Ctschrepe Avepue CHECKED BY: GATE:disposed,reproduced In whole or part,nor used In conjunction with the Ponnsboro,WV 26415 <br /> design,manufacture of repair of goads for anyone other than Simonton V L ME: Decimals Angles SCALE; SHEET; APPRV'D BY: DATE; <br /> Windows without Its consent.This restriction does not limit line <br /> recipient's rights to utilize Information contained In this document whIch SURFACE AREA: P 0.M R: A*.03 FIT 1 of 1 <br /> Is property obtained from another source. .XX*.01 0°30 In. SERIES: 75-75 75-09/07-75 <br /> FlNISH TREATMENT: .XXX*.005 D7-09/07-10/07-20 DOUBLE HUNG <br /> TITLE: <br /> FlLE:FL 5176.15 2X BUCK INSTALLATION(AS TESTED) <br />
The URL can be used to link to this page
Your browser does not support the video tag.