Laserfiche WebLink
MODEL DESIGNATION: Simonton Double Hung Series 43-17 Vinyl Window <br /> ,,%%' ,%ORcW <br /> MAXIMUM OVERALL NOMINAL SIZE: See Size Chart 9/27/2019 <br /> NO 5IB201 LUCAS A. TURNER, P.E. <br /> DESIGN PRESSURE RATING: See Size Chart FL PE # 58201 <br /> TURNER ENGINEERING & <br /> CONSULTING, INC. <br /> USABLE CONFIGURATIONS: X ' STATE OF <br /> 0 4rt;a (COA # 29779) <br /> 2428 OLD NATCHEZ TRACE <br /> GENERAL DESCRIPTION: The head,sill,and side iambs are extruded PVC.The wall thickness TRAIL, CAMDEN, TN 38320 <br /> PH. 941-380-1574 <br /> through which the anchor screw penetrates Is a minimum of 0142". <br /> TABLE 1: INSTALLATION FASTENERS TABLE <br /> IDI SUBSTRATE TYPE ANCHOR TYPE MIN. EMBED MIN.TAEDNCGEE <br /> DIS <br /> A CONCRETE (2 KSI MIN.) 3/16" ITW TAPCON_ 1-1/2" 1 1/8'. <br /> 8 <br /> HOLLOW OR GROUT-FILLED CMU 3/1r. ITW TAPCON 1. 2' <br /> (ASTM C90) (117 PC MIN. <br /> C 2X MIN. SOUTHERN PINE WOOD 3/16" ITW TAPCON 1-3/8- 3/4- <br /> -(G=0.5 ) <br /> I, 2X MIN. SOUTHERN PINE WOOD #10 WOOD SCREW 1-3/8" 3/4' <br /> (G=0.55) <br /> 16 GAUGE (0.060") MIN. STEEL #10-16 ITIN TEKS FULL THREAD 1/2- <br /> E STUD. 33KSI YIELD 1% SELF-DRILLING SCREW I <br /> F ',/"' ALUM. 6063-T5 IN. OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD 1/2- <br /> /8" STEEL 36 KSI MIN. I DRILLING SCREW <br /> NOTES: <br /> I.This Installation has been evaluated for use In locations adhering to the Florida Building Code outside the HVHZ,and where pressure requirements as determined by ASCE 7 Minimum Design Loads for <br /> Buildings and Other Structures do not exceed the design pressure ratings herein. <br /> 2.For anchorage requirements in various substrates see Table 1. A minimum distance of 3"shall be maintained between any two installation fasteners. <br /> 3.All interior and exterior perimeter surfaces of the window must be caulked. <br /> 4.Anchor type,size,spacing,embedment,and edge distance shall be as specified In these drawings. <br /> 5.Anchor embedment to substrate shall be beyond wall dressing or stucco.For masonry openings with wood bucks less than 1-1/2"thick,embedment shall be beyond wood bucks,if used,and Into <br /> masonry substrate.Wood bucks with masonry are optional. <br /> 6.Wood or masonry openings.-bucks,and-buck fasteners,by others,shall be properly designed and Installed to transfer wind-loads to the structure. <br /> 7.The responsibility for selection of Simonton products to meet any applicable local laws,building codes,ordinances,or other safety requirements rests solely with the architect,building owner,or <br /> contractor.. <br /> 8.Shims are required where gaps of greater than 1/16"exist between opening and frame.Max.shim stack Is 1/4". Shims shall be load-bearing and capable of transferring loads to the substrate. <br /> 9.When used in areas requiring impact protection,this product REQUIRES the use of approved impact resistant shutters or other external protection. <br /> 10.Sealing and flashing by others should be applied using the ASTM E 2112 methodology appropriate for the opening Into which the product Is being installed.Overall water penetration resistance of the <br /> installed product Is not addressed in this drawing and is the responsibility of others. <br /> 11.Glazing shall comply with ASTM E 1300-04. <br /> 12.All fasteners penetrating Into pressure treated wood shall be capable of preventing corrosion due to reaction with pressure treatment chemicals. Any dissimilar materials that come Into contact shall <br /> be protected to prevent reactions In accordance with c'ode requirements. <br /> 13.A wind load duration factor Cd=1.6 was used for the analysis of wood screws only. <br /> 14.Products shall be constructed as specified in test reports D2 310.01-501-47,C3526.01-501-47 and C3522.01-501-47 by Architectural Testing,Inc-Springdale,PA and C5630.01-109-47 and <br /> C2276.01-109-47 by Architectural Testing,Inc-York,PA. <br /> 15.Use 100%pure silicone caulk compliant with AAMA 800 Section I -Sealant Specifications for use with Architectural Fenestration Products. Make sure surfaces are completely free from all old caulk, <br /> damaged wood,wood fibers,grease,oil dirt,rust,mold or similar contaminants.Vacuum and clean opening surfaces completely.A fully primed surface Is recommended,but not required.Cleaning <br /> of all surfaces should be done the same day of which the silicone caulk Is to applied.For more details visit Slincinton.com. <br /> 16.Caulk application:recommended air and surface temperatures at the time of application are to be between 40 and 90 degrees F. Insure all contact surfaces are clean and dry Including the new <br /> window(s). Use a backer rod on all joints>3/4"deep and/or wider than 1/4". Finished caulk joint should be a minimum of 3/8"deep and make full contact with both the new window and structural <br /> opening surfaces.Silicone caulk should be forced Into joint or compressed to assure full contact on both surfaces and to expel any air pockets. <br /> MATERIAL. size. ND.: <br /> -B 1 34 <br /> DISCLOSURE STATEMENT RMS RNISR T.Ie.- 00 M <br /> . SIMON DRAY;N BY: <br /> Me&­rd is the gnepedy.t Simonton Whd.-."10 Wn,a M ft pddq MF Al Ur4S Otherwise Spodnad W I " D * JDATF-i <br /> H <br /> end nin-Ighn,1.1. ubj..matter.matter.Thl,documentern N p-IdW 1.thedpl.nt ALLOY&TE ER" I Cochranee Avenue L, 03aon? <br /> on the p,-d eenfiga.Awl 0 Hnot to be dBefeeed,repd..d I-Inel- P.-b..,WV 26415 CHECKED BY-.JDATE., <br /> pod.-..d in con unc4onwIXh the d.,10n,nwnuradur4-onkageeft IW WIONT, TG-LUMF- Oedmets Angles <br /> anode <br /> e1h.,0-SinnnRen Wind-*Ib..1 Ile-.1.Thh­14,11-d.. SCALE: ISHEET: APPRVT)BY-. DATE <br /> net ftmft the reciplern's agnis I*utir2e Intermit..­Wh.d In Ads document SURFACE p - FIT 2.12 <br /> AREA: unnum .xx 1.01 0,30.I.. SERIES: <br /> FINISH IREATMENIR. Xxx 1.005 4340140d5 DOUBLE HUNG <br /> TITLE: <br /> !FILE FL 5167 1XIBLICKINSTALLAMON <br />