Laserfiche WebLink
REY. REMSIONS MSED BY DATE: <br /> MOn DESIGNATION: Simonton Series 06-05 2-Panel Vinyl Patio Door NO P.E. SEAL REQUIRED <br /> INSTALLATION SUPPORTED 2 UPDATED NOTES,GENERAL DESCRIPTION,AND T.D.D. 04/05/11 <br /> MAXIMUM OVERALL NOMINAL SIZE' See Size Chart BY AAMA TEST REPORTS 3 ADDED SIZES PER NEW TESTING, 'T.D.D. O5/04/11 <br /> DESIGN PRE,�SURE RATi G: See Size Chart <br /> fiD X 2 1/2'MIN.WOOD 4 ADDED GLAZING DETAILS. T.D.D. 08/20/ii <br /> USABLE CONFIGURATIONS: XO, OX SCREW WITH 1.50'MIN. 5 ADDED GLAZING NOTE AND UPDATED SIZE T.D.D. 03/11/13 <br /> EMBEDMENT INTO WOOD 2X BUCK <br /> MIN.EDGE DIST,SEE NOTES 8 ADDED MIN.EDGE DIST,NOTE B.&S, 05/17/15 <br /> GENERAL DESCRIPTION: The head, sill, and side jambs are extruded PVC. The wall thickness 7 UPDATED SIZE CHART&ANCHOR SPACING LMH 11f23/15 <br /> through which the anchor screw penetrates is D minimum of 0.070". SILICONE CAULK <br /> SEE NOTES 11 &12 <br /> 1/4'MAX.SHIM SILICONE CAULK <br /> SEE NOTES 11&12 <br /> 3' 6" AA <br /> 4'MAX,SHIM <br /> 6"'{—I 3"—I 1— REQUIRED <br /> CONE CAULK <br /> E NOTES 11 &12 <br /> SILICONE CAULK <br /> -...HEAD <br /> SEE NOTES 11 &12 2X BUCK <br /> SILL <br /> 2X BUCK SILICONE CAULK <br /> SEE NOTES 11 &12 SILICONE CAULK <br /> SEE NOTES 11&12 <br /> 1/4'MAX.SHIM 2X BUCK <br /> 1 j4'MAX SHIM <br /> _ /8 X 2 1/2'WOOD <br /> W v fB X 2 1/2'MIN. /10 X 2 1/2'MIN,WOOD SCREW THROUGH KEEPER <br /> ow <br /> KEEPER WOOD <br /> BUCK MA EMBE MENREW T{INTOO WOOD INTO WOOD <br /> MAX. MIN.EDGE DIST.,SEE NOTES <br /> < ( O.C. SPACING !f S X 2 t NIT MIN. MIN. <br /> p� SEE SIZE CHART SCREW WITH TO MIN. <br /> WOOD <br /> OO x _1 SILICONE CAULK EMBEDMENT INTO NOTES <br /> � MIN.EDGE DIST.,SEE NOTES <br /> SEE NOTES 11&12 <br /> IN <br /> x FIXED PANEL JAMB SEE NOTESAULK 1 &12 <br /> KEEPER JAMB <br /> NOTES: <br /> 1,This Installation has been evaluated for use in locations adhering to lhe,Texas&Florida Building Codes and where pressure requirements as determined by ASCE 7 Minimum <br /> Design Loads for Buildings and Other Structures do not exceed the design pressure ratings herein,for use outside the H.V,H.Z <br /> 2.All exterior perimeter surfaces of the door must be caulked.Interior caulking Is optional unless noted otherwise. <br /> 3.Anchors shall be specified and spaced as shown.Anchor embedment to base material shall be beyond wall dressing or stucco and Into wood, <br /> 4,The responsibility for selection of Simonton products to meet any applicable local laws,building codes,ordinances,or other safety requirements rests solely with the architect, <br /> / building owner,or contract- <br /> S.Shims are optional.Maximum shim stack is/14". <br /> 6.Woad bucks(try others)must be engineered and anchored properly to transfer loads to the structure. <br /> UNIT WIDTH ..When used In areas requiring Impact protection,this product REQUIRES the use of approved Impact resistant shutters or other external protection. <br /> 6.Flashing should be applied using the ASTM E 2112 method appropriate for the opening Into which the door Is being Installed. <br /> 'W"MAX. OVERALL FRAME WIDTH 9,installation anchors should be at least 3f4"from the edge of the wood. <br /> 10.Glazing shall comply with ASTM E 1300 and safety glazing requirements per Florida Building Code section 2406. <br /> 11.Use 100%pure silicon caulk. Make sure surfaces are completely free from all old caulk,damaged wood,wood Rbem,grease,all dirt,rust,mold or similar contaminants, <br /> Vacuum opening surfaces completely.A fully primed surface Is recommended,but not required,Cleaning of all surfaces should be done the someday of which the silicone <br /> caulk Is to applied.For more details see"New Construction Installation Instructions"on Simanton.com. <br /> SIZE CHART 12.Caulk application:recommended air and surface temperatures at the time of application are to be between 40 and 90 degrees F.Insure all contact surfaces are clean and dry <br /> OVERALL SIZE 0.0, including the new window(s).Use a backer rod on all Joints�3/4"deep andlorwidar than 174•. Finished caulk joint should be a minimum o1316'deep and make foil contact <br /> WIDTH JHFIII SPACING DP RATING with both the new window and structural opening surfaces.Silicone caulk should be forced Into joint or compressed to assure full contact on both surfaces and to expel any air <br /> pockets. <br /> 71" 96" 17" _ <br /> BAA <br /> 5" 8O' 23" ±35 PSF DISCLOSURE STATEMENT �SIMONTON' B IN0412 7 <br /> 71" 80" 23' This document Is the property of Simonton Mndow&which S Dimensional Tolerances : <br /> 71' BD" 23' *50 PSF retain,all proprietary and other rights to Its sub)ect matter, C Unless Otherwise Saecified w r N o o w s T.D.D. jU`a'41t/:ID/09 <br /> This document Is provided to the r alplont on the xproeaed 0 1EMP 1 Cachrsne Avenue CHECKED une DATE: <br /> CIRCLED ANCHORS REQUIRED ONLY FOR —dill..thatIt is not to be dlsdoeed.rsproduaed M whole ar Peonaboro,WV 26415 <br /> 95x8D AND 71x80-DP35. part,norused in con)—floe with the design,manufacture or Decimals Angles ALE: HEET: APP•- DY:DATE: <br /> repair,or goods for anyone other than Simonton Windows <br /> wllhout Its consent This restriction does not limit the %*,pJ ITT 1 of 1 <br /> ZIP' <br /> rights to utilize Information contained In this URFACE AREA: j(% 01 0' JO min. S RIES: <br /> document which is <br /> property obtained from another source. NISH TREATMENT: .XXX#.DOS 05-05 2-PANEL PATIO DOOR <br /> nTLE: <br /> FILE:IN0412 2X BUCK RETROFIT INSTALLATION(AS TESTED <br />