Laserfiche WebLink
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> LOT 55, OAKS OF PASCO <br /> AS RECORDED IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br /> ON LOT CALCULATIONS <br /> LOT 5,750 SQ. FT. <br /> LIVING AREA 1,651 So. FT. <br /> GARAGE a 416 SQ. FT. <br /> ENTRY 100 So. FT. <br /> LANAI = 260 S0. FT. <br /> PATIO = 0 So. FT. <br /> DRIVEWAY 328 So. FT. <br /> A/C PAD v 9 SO' FT. <br /> WALKWAY = 30 SO. FT. <br /> IMPERVIOUS = 49% <br /> 2794. So. FT. <br /> SOD = 2,956 SO. FT. a <br /> OFF LOT CALCULATIONS <br /> RIGHT OF WAY 400 SO. FT. <br /> DRIVE APRON - 57 SO. FT. z <br /> PUBLIC S/W - 250 SO. FT. 1" = 30• <br /> SOD - 93 SO. FT. GRAPTOT H�I SCE^ <br /> AREA = 6,150 SO. FT. 0 15 30 <br /> DRIVEWAY - 385 SQ. FT. <br /> SIDEWALK - 280 SQ. FT. <br /> SOD - 3.049 SQ. FT. <br /> 1.7 <br /> 171 <br /> $'v a`2o go <br /> ti <br /> o <br /> v' i I <br /> P / � I �I <br /> N820.0 6'E <br /> T 20.00• mCD <br /> n B <br /> N85'42''�6 E --aw � <br /> 115.00' <br /> 48.7 I o �, O ;aU1 29.B 1f,.0`; I I z <br /> AJ <br /> gl0 -t PBGPosEo I p IY= x O <br /> FlNISNED FLOC DR 02 20.5 _; K1� '�>v <br /> c>iAI m�ICR g! ELEVATON�91.26 4's.a ' ::';:m,� I y <br /> OD rri <br /> 64.67 20.5' O n <br /> > LTI <br /> O I / 64.7 <br /> O A �' 1 <br /> •39.8•O <br /> 9 S85'42'16"W A^0 <br /> a9m�115.00' m ' a I <br /> 1 <br /> o <br /> PREPARED FOR: <br /> BUILDING SETBACKS <br /> FRONT: 20• <br /> REAR: 10 <br /> SIDE: 5• <br /> SIDE STREET: 15• LEGEND: <br /> NOTES: —•—•— BUILDING SETBACK LINE PI POINT OF INTERSECTION <br /> PL POINT OF CURVATURE <br /> 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED —-— CENTERLINE PT POINT of TANGENCY <br /> ON THE APPROVED ENGINEERING PLANS PREPARED —__ RIGHT OF WAY LINE RP RADIUS POINT <br /> BY CORNELISON ENGINEERING&DESIGN INC. XtltIX PROPOSED ELEVATION PRC POINT OFF REVERSEOCURRVATURE <br /> 2. ELEVATIONS ARE BASED ON NAVD 1988 J 7PCPYP TYPICAL <br /> DATUM. PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (C) PER PLAT <br /> ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PB CALCULATED <br /> THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER prs PLAT BOOK <br /> OWNER ARE REQUIRED TO VERIFY ALL SETBACKS,BUILDING S/W SIDEWALK SO.FT. SQUARE FEET <br /> DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A.FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> CONSTRUCTION. F.LR.M. FLOOD INSURANCE RATE MAP <br /> NAVD NORTH AMERICAN VERTICAL DATUM <br /> THIS IS NOT A SURVEY SEE oRANARTAARGE�wEASEMENT <br /> THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT <br /> BLOOD NOTE: I HAVE EXAMINED THE FLR.M.MAP NO.121DICD289F SURVEYOR NOTES: <br /> LA"PR <br /> 9/26/20I4 AND FOUND THE SUBJECT PROPERTY APPEARS TO UE 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> Y IN ZONE'X'&'Ar.ZONE'X',AREAS DETERMINED TO BE LAND SHOWN HEREON FOR EASEMENTS,RIGHT <br /> THE 0.2><ANNUAL CHANCE ROODPWN.ZONE'AE' AREAS <br /> ED TO BE SPECIAL FLOOD HAZARD AREAS SUBJECT 40 OF WAY,RESTRICTIONS OF RECORD WHICH <br /> ON BY THE UL ANNUAL CHANCE FLOOD EVENT.BASE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND. <br /> GUDNS DETERMINED 1D BE 885•.THE SURVEYOR MAKES NO <br /> '5NI <br /> IS AS TO THE ABOVE INFORMATION.PLEASE CONTACT THE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> .M.A AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. <br /> deOWNO; 'DOD HEREON EINE BASED ON THE R PLA. OF 3. NOT VALID WITHOUT THE AUTHENTIC <br /> GODS ORIYE BONG N041744W,PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> ELECTRONIC SEAL OF A FLORIDA LICENSED <br /> DATE)` REVISED:, M E F?I CAN SURVEYOR AND MAPPER. <br /> U F?V EY 1 N G a9m�g^e'� �""�" ^ <br /> :PTO FEET �vvv,w b by.) WSdVED BY;\,� a MAPPING INC.CERTIFICATION OF AUTHORIZATION NUMBER LB16393arc �. 1911P�107 55 3191 MAGUIRE BOULEVARD,SUITE 200 `•' f� . . ` THE <br /> 1 ORLANDO,FLORIDA 32B03 ' Adbe Ao,t wnwrc tt.a23 FIRM <br /> BN RIAB. (407)426-7979 ^„ DALE <br /> 1 PLOT PLAN 09 03 2020 JIG WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM#6485 <br />