Laserfiche WebLink
d <br /> 21 Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 ME.0 <br /> 24. In accordance with the Land Development Code, lots_ .shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> Insulation for hot water'pipe with a minimum thermal resistance (R-value) of R-3 shall be. applied to the <br /> following:: <br /> Piping V.inch (19.1 mm) and larger in nominal diameter.. <br /> Piping,serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to a distribution mbri foid., <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be proviided before C.O: <br /> 26.A coon of the enemy cacls shafl be with permit at all times' <br /> 27. Coon of f nal insulation"reyort shaft be provided ivith permit before r1naL <br /> 28. No fence,pool onscreen-enclosure is issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code Oh Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />