Laserfiche WebLink
D <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.T.E.shall be a minimum of 8" above the road elevation and,an engineered site plan. <br /> 2: Lots shall.be graded to comply-with-R401.3.-of the F:B.C: <br /> I Compactiori test required if 2411 or more,of fill dirt is brought in at any one place. <br /> -4: Tie in survey required before pouring concrete. <br /> 5; .Driveways re ea R.O:W. use permit, All 4 sides of dn*vewaythru the sidewalk shall have <br /> expansion material., <br /> 6: All setbacks shall be met. <br /> 7: All property markers shall be uncovered,and marked at time of first 4nspecti6n. <br /> 8: All A.D..A.requirements shall be met:, <br /> 9: No electric,.plumbing;mechanical,or framing shall.be_covered without an inspection.and . <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances.shall not be installed in a location where subject to mechanical.damage unless <br /> protected by:approved barriers: M303:4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for A/C units shall be raised at least 3"above finished grade. M1308:1. <br /> 146 Return air in-all bedrooms. F.B.C. M1620:4 <br /> 15. Smoke detectors.are to be installed in accordance with RM-.1 of the F.B.C_. <br /> 16:All glazing requirements are to be in accordance with R308A of the F.B.C; <br /> 17-All means.of egress are to be in accordance with RM I of the F.B.C.. <br /> 18: "Green gypsum board" shall not be used as a backer in showers or-tubs. R702:4.2 F.B.C. <br /> .. <br /> 19:.Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage.' They shall be installed in accordance.with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all. <br /> underground:plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />