Laserfiche WebLink
Data Sheet Enphase IQ 7 and IQ 7+Microinverters <br /> Enphase Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-8-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US <br /> Region:AMERICAS <br /> 'Commonly used module pairings' 235 W-350 W+ _ _235 W-.440 W+' <br /> Module compatibility 60-cell PV modules only 60-ce11 and 72-cell PV modules <br /> Maximum input DC voltage - 48 V - 60 V- <br /> Peak power tracking voltage 27v-37V 27V-45V <br /> Operating range 16 V-48V- 16V-60V _ <br /> Min/Max start voltage 22V/48V 22 V 160V <br /> Max DC short circuit current(module Isc) 15 A 15 A - <br /> Enphase The high-powered smart grid-ready Overvoltage class DC port II II <br /> Enphase IQ 7 Micro'and Enphase IQ 7+Micro' DC portbackfeedcurrent OA oA <br /> PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; <br /> IQ7 and IQ 7+ dramatically simplify the installation process while AC side protection requires max 20A per branch circuit <br /> achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microlnverter IQ 7+Microinvarter <br /> Microinverters Peak output power 250 VA 295 VA <br /> Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA <br /> IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range' 240 V/ 208V/' 240 V/ 208V/' <br /> g p 211-264 V 183-229 V 211-264 V . 183.229 V <br /> IQ Envoy',Enphase IQ Battery'",and the Enphase Maximum continuous output current 1.0A(240V) 1.15A(208V) 1.21A(240V) 1.39A(208V) <br /> Nominal frequency60 Hz '60 Hz-" <br /> Enlighten"'monitoring and analysis software. <br /> Extended frequency range 47-68 Hz 47-68 Hz <br /> QSeriesMicroinvertersextendthereliability ,AC short circuitfawccurrent over 3cycles 5.8Arms S.BArms <br /> Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) <br /> standards set forth by previous generations and Overvoltoge class AC port _ ul ul <br /> undergo over a million hours Of power-on testing, AC port backfeed current - 0 A _ JA <br /> enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 ' <br /> Power factor(adjustable) 0.85 leadin6...0.85 legging 0.85 leading 0.85 lagging <br /> warranty of up to 25 years. EFFICIENCY @240 V @208 V @240 V @208 V <br /> Peakefficiency _ __ __ 97.6% _ 97.6% _97.5% _ _ _'97.3% <br /> CEC weighted efficiency 97.0% w..0% 97.6% 97.0% <br /> MECHANICAL DATA <br /> Ambient temperature range •40sC to+65°C <br /> Relative humidity range 4%to 100%(condensing) <br /> Easy tO Install Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US)-MC4(or Amphenol H4 UTX with additional Q-DCC-S adapter) ': <br /> Connector type(IQ7-60-B-US$IQ7PLUS-72-B-US) Friends PV2(MC4 lntermateable). <br /> r� Lightweight and simple Adaptors for modules with MC4 or UTX connectors: <br /> Faster installation with improved,lighter two-wire cabling -PV2 to MC4:order ECA-S20-S22 <br /> J -PV2 to UTX:order ECA-S20-S25 <br /> Built-in rapid shutdown compliant(NEC 2D14$2017) Dimensions_(WxHxD) _ - , 212 mm x175 mm x-30.2 mm(without bracket)•f Weight 1.08 kg(2.381bs) <br /> Productive and Reliable Cooling Natural convection-No fans <br /> Approved for wet locations Yes <br /> •optimized for high powered 60-cell and 72-cell*modules Pollution degree PD3 <br /> •More than a million hours of testing Enclosure Class II double-insulated,corrosion resistant polymeric enclosure <br /> •Class II double-insulated enclosure Environmental category/UV exposure rating NEMAType 6/outdoor <br /> •UL listed FEATURES <br /> p Communication Power Line Communication(PLC) , <br /> Monitoring Enlighten Manager and MyEnlighten monitoring options. <br /> Smart Grid Ready Both options require Installation of an Enphase IQ Envoy. <br /> Disconnecting means The AC and Dc connectors have been evaluated and approved by UL for use as the load-break <br /> •Complies with advanced grid support,voltage and disconnect required by NEC 690. <br /> frequency ride-through requirements Compliance CA Rule 21(UL 1741-SA) <br /> Remotely updates to respond to changing UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B.ICES-0003 Class B, <br /> grid requirements CAN/CSA-C22.2 NO.107.1-01 <br /> This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and <br /> •Configurable for varying grid profiles NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,forAC <br /> •Meets CA Rule 21(UL 1741-SA) and DC conductors,when Installed according manufacturer's Instructions. <br /> U� The 10 7+Micro is required to support 72-cell modules. 1.No enforced DC/AC ratlo.See the compatibility calculator at <br /> 2.Nominal voltage range can be extended beyond nominal If required by the utility <br /> 3.Limits may very.Refer to local requirement,to define the number of mlcroinvenera per branch in your area. <br /> To learn more about Enphase offerings,visit enphase.com V E N PH AS E. To learn more about Enphase offerings,visit enphese.com v EN P H AS E. <br /> 0 2018 Enphase Energy.All rights reserved.All eademorks or brands used are the property of Enphase Energy,Inc <br /> 201811-19 <br />