Laserfiche WebLink
.23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots.shall be scjdded before final at least.l0 <br /> . . <br /> feet around the structure: <br /> 25. R403.5.3Hot water.pipe insulation <br /> insulation for hot water. pipe-with a minimum thermal eesistance (R43lue) of R-3 shall be applied to the <br /> following: <br /> Piping 31. inch (19.1 mm) and larger-in.nominal diameter: <br /> Piping serving rriore than one dwelling unit. <br /> Piping located outside the conditioned space.. <br /> Piping fcom the:water heater to.a distribution manifold: <br /> Piping.located under.a floor slab: <br /> Buried in piping,' - <br /> Supply and return piping in recirculation systems other than demand recirculation systems: <br /> 25.Blower door test shall be provided Before C.O: <br /> 26.A copy of the enerew.cacls shall be with permit at all limes <br /> 27 Cope offfinal insulation report shalt be provided with permit before rinaai. <br /> 28.No fence, pool or screen enclosure is issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way _ <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric_Code(2016) <br />