My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-873
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-873
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2022 2:00:51 PM
Creation date
2/27/2022 2:37:57 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-873
Building Department - Name
SCOTT,CHRISTI & JOHN
Address
36005 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S <br /> DocuSign Envelope ID:04ABE31B-282A-4C4C-8840-FC4EE5C83747 <br /> 3. The following mounting types shall be used. Please refer to the mounting details for the associated mounting <br /> method requirements. Based on our evaluation, the uplift demand is less than the maximum allowable per <br /> mount and therefore is adequate. <br /> • RL-U SpeedSeal: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) <br /> of timber construction specifications for Southern Pine is 235 Ibs/inch penetration. <br /> 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2017 FBC <br /> 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. <br /> 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the <br /> wind load uplift procedures of ASCE 7-10. These spacing requirements apply to all mount types indicated <br /> above. The following values have been verified by in-house testing and the mounting hardware manufacturers' <br /> data, which are available upon request. Panel support connections should be staggered, where possible, to <br /> distribute load to adjacent members. <br /> Modules in Landscape Modules in Portrait <br /> Roof Zone Interior Ede Corner Interior Ede Corner <br /> Max Vertical Spacing in 40 40 40 66 66 66 <br /> Max Horizontal Spacing in 48 48 48 48 48 48 <br /> Cantilever in 16 16 16 12 12 12 <br /> D. Summary <br /> Based on the above evaluation, with appropriate panel anchors being utilized, the roof system designed on will <br /> adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has <br /> been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida <br /> Building Code- Residential 6th Edition, current industry standards and practice, and the information supplied to us <br /> at the time of this report. <br /> If there are any questions regarding the above, or if more information is required, please contact me. <br /> \\�N\\IIIIIIII///// <br /> Regards, ��� �� <br /> J. Matthew Walsh, PE Nc+ 84�p ( �. <br /> FL License No. 84923 — * , <br /> EDocuSigned by: STATE OF <br /> �...n`.Li, • ` <br /> 7AEEB20514FE4D2... �/ �,tORtOP''�j� <br /> Matthew Walsh �/S®NII AI 10���\`\ <br /> September 30,2020 19:44 AM MDT 09/30/2020 <br /> This item has been electronically signed and sealed by Matt Walsh using a Digital Signature and date.Printed copies of this <br /> document are not considered signed and sealed and the signature must be verified on any electronic copies. <br /> Page 2 of 2 ,Y,i' Li�,� -3s a r <br />
The URL can be used to link to this page
Your browser does not support the video tag.