My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-879
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-879
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2022 2:40:57 PM
Creation date
2/27/2022 2:40:56 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-879
Building Department - Name
ROSELLO ANGELO & RUTH E LINVING TRUST
Address
5424 10TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cool and Cobb Engineering Company <br /> Date: 8 13 20 <br /> Job: Ruth Rossello <br /> Location: 542410th St <br /> Zephvrhills, FL 33542 <br /> PILING DESIGN ANALYSIS <br /> The load requirements for the pilings designed to assist in supporting the identified areas of the subject <br /> residence were determined.The selected piling locations and the specific piling are identified on the Pier <br /> Identification and Location Plan attached.The calculated total loads on the piles in the specific location, <br /> including both dead and live loads are documented in the attached table which is designated as Attachment"A". <br /> Based on the total load requirements for each of these piles,the 7 k driver is to be employed.The 7 k torque <br /> driver should be employed with a selected gauge pressure of 1000 psi,which will provide pile capacity, <br /> including the 2 to 1 safety factor of 21,600 lbs.which is greater than the maximum calculated total load of <br /> 10,800 lbs.which occurs on the pile identified as no. A-1 . Based on this analysis,the use of the 7 k torque <br /> driver for the Ram Jack piles with a specific gauge pressure of 1000 psi and a minimum depth of 10'is <br /> approved and certified as meeting all of the requirements of the Florida Building Code 2017 6th Edition,and good <br /> engineering practice.This is not to be the primary support structure,but a supplement support to assist in <br /> support of the weight of the structure,which will reduce the total pressure on the existing soils.After <br /> completion of installation,Cool and Cobb Engineering Company shall be supplied with a drilling log of the <br /> location and depths of each pile installed so they can evaluate the installation and prepare the"As Built" <br /> drawings. <br /> General Notes: <br /> 1. All piles to be installed in accordance with ICC ES AC 358 <br /> 2. A log of each pile to be kept by Contractor noting depth and final torque installed for each pile. <br /> 3. Minimum pile depth to be 10'-0" <br /> 4. Helical piles installed less than 48"apart are to be battered 10°away from each other. <br /> 5. This design is based on the loads of the structure placed on the shallow soils under the structure. <br /> 6. No deep soils geotechnical testing information was provided for this design. <br /> 7. This design does not address any possible sink hole activity as defined in Florida Statute§627.706. <br /> 8 13 20 <br /> Carl Cool, P.E. ALL WORK SHALL COMPLY WITH PREVAILING <br /> State of Florida CODES FLORIDA BUILDING CODE, <br /> Professional Engineer No.16921 NATIONAL ELECTRIC CODE, <br /> AND THE CITY OF ZEPHYRHILLS <br /> ORDINANCES OCT 203 W.Main St. <br /> REVIEW DATE � S 2020 Avon Park,FL 33825 <br /> CITY OF ZEPHYRH1--.1:-�-" Office:(863)657-2323 <br /> FLAN EXAMINER Fax: (863)657-2324 <br />
The URL can be used to link to this page
Your browser does not support the video tag.