Laserfiche WebLink
• NFISp The Association of <br /> ® Pool&Spa Professionals' <br /> ANSVAPSPACC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS <br /> PROJECT NAME: MAHON PROJECT CONTRACTOR NAME Hometown Pools and Pavers <br /> AND ADDRESS AND ADDRESS: <br /> 38541 Trellis Avenue 35386 Lake Ray Drive <br /> Zephyrhills,FL 33540 Dade City, FL 33525 <br /> KNER:Lee and Tracy Mahon CONTRACTOR PHONE:(352)588-5077 DAB'9/17/2020 <br /> This information sheet was prepared by the APSP-15 Residential Swimming Pool and Spa Energy Efficiency Standard Writing Committee of the Association of Pool and Spa <br /> Professionals(APSP). It is not part of the American National Standard ANSI/APSP/ICC-15 2011 but is included for information only.Contractors should acquire and comply <br /> with the ANSI/APSP/ICC-15 2011 standard which can be purchased at www.apsp.org. <br /> 1. §5.2.1:Calculated pool volume <br /> a. Gallons: 15000 ;or 1. 15000 gallons _ <br /> b.Calculated Gallons: (surface area)X (average depth)X Z48 (gal/ftA3) = 0 <br /> 2.§5.2.1:Calculated maximum filtration flow rate 2. 42 gpm _ <br /> (Pool volume_360 or 36gpm whichever is larger) <br /> 3.§5.2.2:Auxiliary Pool Load: flYes,ELNo? <br /> (Enter the highest'auxiliary pool load"to be powered by the swimming pool filtration pump.Do not add auxiliary 3. gpm _ <br /> pool load flow rates together,only the highest is used.) <br /> 4. Calculated maximum flow rate 4. 42 gpm _ <br /> (Item 2 or item 3,whichever is larger.) <br /> S.§5.5.1:Pipe sizing: <br /> a.Minimum suction pipe diameter 5a. 2•0 inches _ <br /> (Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the some or more than item 4.) <br /> b.Minimum suction branch pipe diameter 5b. 2.0 inches _ <br /> (Calculate.Item 4. 42 (gpm)_Branch Pipes 1 (quantity)=branch flow rate 42 (gpm). <br /> Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the some or more than the calculated <br /> suction branch flow rate.) <br /> c.Minimum return pipe diameter Sc. 1.5 inches _ <br /> (Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than item 4.) <br /> d.Minimum return branch pipe diameter 5d. 7.5 inches _ <br /> (Calculate.Item 4. 41 (gpm)_Branch Pipes 1 (quantity)=branch flow rate 42 (gpm). <br /> Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than the calculated <br /> return branch flow rate.) <br /> 6.§5.4.1:Filter type and size: <br /> a.Filter type:(Cartridge,DE,Sand) 6a. Cartridge IV <br /> b.Minimum filter area 6b. 111.1 sq.ft. — <br /> (Calculate:item 4. 41 (gpm)-filter factor 0.375 <br /> Filterfactors:Cartrid a=0.375, Sand=15,Diatomaceous Earth=2 <br /> 7. §5.4.2:Backwash valve: Yes, 0 No? <br /> 7. 2•0 inches — <br /> (When using a backwash valve,enter result of item 5c or 2 inches whichever is larger) <br /> Table 1 Pipe Size: 1.5" 2" 2.5" 3" 3.5" 4" 5" 6" <br /> Nominal GPM @ 6 fps 38 63 90 138 185 1 238 374 540 <br /> Nominal GPM @ a fps 51 84 119 194 247 317 499 720 <br /> S.Pump selection: <br /> §5.3.2.1:Pools 17,000 gallons or less,select pump*from the database with a Curve-A gpm flow equal to item 2 or less. <br /> §5.3.2.1:Pools 17,001 gallons or more,select pump*from the database with a Curve-C gpm flow equal to item 2 or less.*Multi- <br /> speed pumps must have one speed listed that satisfies this requirement. <br /> a.Pump model 8a, Super Max <br /> b.Pump flow 8b. 42 gpm _ <br /> (§5.3.2.1,5.3.1.2:Applicable Curve A or C gpm flow listed in database) <br /> 4/4/12 ANSI/APSP/ICC-15 Standard Writing Committee Form 1 of 2 <br />