My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-887
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-887
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2022 2:03:29 PM
Creation date
2/27/2022 2:47:57 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-887
Building Department - Name
MCWILLIAMS,DANIEL & KATHY
Address
37153 NEUKOM AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALLATION DETAILS FOR INTEGRAL FIN&J-CHANNEL FRAMES INSTALLATION OPTION 6 INSTALLATION OPTION 5 <br /> ANCHORED THROUGH FRAME ANCHORED THROUGH INTEGRAL FIN <br /> INTO 2X WOOD FRAME OR INTO RX WOOD FRAME OR EDGE DISTANCE <br /> INSTALLATION OPTION 5 EMBEDMENT BUUK51 KIP.SEE NOTE 2,THIS BUCKSTRIP.SEE NOTE 2,THIS SHEET. <br /> ANCHORED THROUGH INTEGRAL EMBEDMENT SHEET. <br /> FIN INTO ZX WOOD FRAME OR (11l114"MAX SHIM 16 1/4'MAX SHIM <br /> BUCK-STRIP,SEE NOTE 2,THIS EDGE DISTANCE <br /> SHEET. TYP.ANCHOR TYPE, VISIBLE 17 <br /> J-CHANNEL EMBEDMENT AND EDGE_ 00 18 LIGHTWIDTH <br /> FRAME DISTANCE PER SUBSTRATE, <br /> SHOWN SEE TABLE 2,SHEET 2. BALANCE <br /> 44 TYPE BOTTOM EMBEDMENT <br /> VARIES SASH <br /> Lj <br /> 114"MAXSHIM 42 WITH BASH <br /> TYP.ANCHOR TYPE, EDGE WEIGHT 54 30 <br /> EMBEDMENT AND EDGE DISTANCE n I — 31 —1 <br /> DISTANCE PER SUBSTRATE, TOP <br /> SEE TABLE 3,SHEET 2. 0 SASH TYP.ANCHOR TYPE, <br /> 18 (MAIL SHOWN) INTEGRAL EMBEDMENT AND EDGE <br /> 85 a 0 II�� VISIBLE FIN DISTANCE PER SUBSTRATE, <br /> LIGHT WIDTH ME SEE TABLE 3.SHEET 2. <br /> J-CHANNEL w D 1 SHOWN (NAIL SHOWN) <br /> FRAME 9) 87 EXTERIOR <br /> 73 19 20 OPT.SASH TOP NOTES- SHOWN BUCK WIDTH <br /> LIFT lu <br /> VISIBLE 1)USE ONLY HORIZONTAL SECTION C-C <br /> LIGHT i 9 SUBSTRATE-APPROPRIATE <br /> HEIGHT ANCHORS LISTED ON TABLES 2&3 <br /> 48 <br /> OF SHEET 2.FOLLOW EMBEDMENT FBc COMPLIANT ALUMINUMISTEEL FRAMING OR STEEL STUD, <br /> 21 WMAX. SHEET 2. <br /> FORALL AND EDGE DISTANCE LIMITS.ANY I SHIM MAY BE VERTICAL OR HORIZONTAL.SEE SUBSTRATE PROPERTIES.TABLES 2&3, <br /> WINDOWS:I INSTALLATION OPTION SHOWN MAY <br /> 22 ANCHOR@ BE D... ON ANY SIDE OFTHE ALSO FOR DADS-APPROVED <br /> 3.56'FROM WINDOW. <br /> END ANDAT #10 OR#12 STEEL 1 W MAX• <br /> 45 46 47 CENTER. 2)MASONRY ANCHORS MAY BE SELF-DRILLING SHIM <br /> BUCK FOR USED INTO WOOD AS PER TABLE 2, SMS(G5),SEE <br /> HEIGHT WINDOWS SHEET 2.ALL WOOD BUCKS LESS TABLES 2&3. <br /> 50 16 OVER 36" THAN 1-112"THtCK ARETO BE SHEET2. <br /> MM ADD CONSIDERED IX INSTALLATIONS. <br /> EXTERIOR 30 ADDITIONAL IX WOOD BUCKS ARE OPTIONAL IF <br /> SCREWS UNIT Is INSTALLED DIRECTLY TO <br /> @16-313- SUBSTRATE.WOOD BUCKS <br /> VISIBLE FROM END. DEPICTED AS 2X ARE i-112"THICK <br /> 66 LIGHT OR GREATER.IX AND 2X BUCKS <br /> HEIGHT (WHEN USED)SHALL BE DESIGNED FIN AND/OR <br /> TO PROPERLY TRANSFER LOADS FLANGE REMOVED <br /> (2) 16 TESTED UNIT TO THE STRUCTURE.WOOD BUCK IN-FIELD <br /> INTERIOR DESIGN AND INSTALLATION IS THE 0 <br /> WEEP 64 LOCATION:6-518" RESPONSIBILITY OF THE ENGINEER INTEGRAL FIN <br /> NOTCHES AT 63 FROM SASH END. OR ARCHITECT OF RECORD. FRAME SHOWN <br /> EACH END. 31 3)VISIBLE LIGHT WIDTH OR HEIGHT INSTAL TION EXTERIOR IN TALLATION PRODUCT REVISED <br /> .27'X 125" 7 30 (ALSO REFERRED TO AS DAYLIGHT OPTION 7 10, ANCHORED THROUGH FRAME INTO EE 38 OPENING)IS MEASURED FROM OPTION 8 as Bu=lying with the Florida <br /> WEEPH Code <br /> W1CCVER@ TYP.ANCHOR TYPE,EMBEDMENT AND BEADING TO BEADING. ANCHORED THROUGH HOA-No. 20-0401.05 <br /> 2.87FROM EDGE DISTANCE PER SUBSTRATE,SEE INTEGRAL FIN INTO METAL METAL(INTEGRAL FINIFLANGE REMOVED) — <br /> EACH END. TABLE 3,SHEET 2.(SCREW SHOWN) 011111", — ReW.fb. — Expiration Bte09/1712025 <br /> 1/4"MAX "'% 0�kY LYNAI"'// C)REVISED DADE MULLION By 9*— <br /> INTEGRAL FIN �/" <br /> GEN Mlamt-Dade Product Control <br /> SHIM <br /> G N SHOWN NOTE. <br /> FRAME SHOWN <br /> 7 VN VISIBLE LIGHT FORMULAS <br /> z*:: No.68705 AK-3/11/20 <br /> No ANCHORS REQUIRED IN WIDTH D-.fpu-. Dr— <br /> FRAME SILL IF ANCHORING T @SASH:BUCK WIDTH-610 J ROSOWSKI <br /> @ FIXED LITE:BUCKWIDTH-7-10 Lo 107oTEcHNoLoGyDRivE J-CHANNEL&INTEGRAL FIN FRAMES <br /> THROUGH THE FRAME. 1,3 93 --� N.VENICE,FL 34275 <br /> INSTALLATION OPTION 5 EDGE DISTANCE HEIGHT(EQUAL-LITE) A EOF l7tf.: <br /> -1600(941Y480 <br /> INSTALLATION-NI 05/15/15 <br /> ANCHOREDTHROUGH BUCK HEIGHT/2-"$" DOUBLE HUNG WINDOW IN Rm <br /> INTEGRAL FIN INTO ZX WOOD--I EMBEDMENT ///,, I AL Suf-/Vom.' sccdw. ShoeC brazing No. <br /> FRAME OR BUCK-STRIP.SEE VERTICAL SECTION D-D A 4 M11YER' P F DH-5460 NTS 4 OF 12 MD-DH5460-01 C <br /> NOTE 2,THIS SHEET. P.E#58705 REGIuTRAnON <br />
The URL can be used to link to this page
Your browser does not support the video tag.