Honeywell <br /> ®SME <br /> ICNIGH'Y' <br /> 5104B <br /> Fire Control Communicator <br /> The Silent Knight Model5104B is a six-zone fire control communicator <br /> providing digital fire reporting over ordinary telephone lines,eliminating <br /> the need for costly leased lines.It's UL 864 and NFPA 72 approved for '® <br /> monitoring local evacuation controls. <br /> As a stand-alone unit,it can be used to monitor: <br /> • Sprinkler systems for waterflow,supervisory,and gate valve tamper <br /> conditions. <br /> • Automatic fire detection systems for structures that are not required to <br /> have a fire alarm system but want property protection(e.g.to call the fire <br /> department after hours). <br /> • Monitors dry contact alarms,trouble and supervisory outputs,then <br /> transmits a separate code for each. <br /> The Model5104B is fully supervised.Its microprocessor constantly runs <br /> programs to monitor AC,standby battery,zone inputs and telephone line <br /> connections.If a fault condition is detected,it sounds a local trouble <br /> audible and reports the condition to the central station.If one of the 5104E <br /> telephone lines faults for more than 60 seconds,it will automatically <br /> switch to the other to report the failure. <br /> The communicator will signal activation,restoration and trouble conditions <br /> on any of the six inputs.If an application requires a different input <br /> configuration,the individual input styles may be changed by using a Model <br /> 7181 Fire Zone Converter Module.The 7181 also allows use of two-wire <br /> type smoke detectors,instead of the normal four-wire contact type,for <br /> automatic fire detection applications. <br /> FEATURES & BENEFITS <br /> • UL 864 Listedas an Six fully supervised Fuseless overload eports in SIA and Asingle, <br /> NFPA 72 Central inputs:one Class A protection with most major programmable output <br /> Station or Remote input,and five Class B automatic reset communications is provided for alarm <br /> Station protected inputs circuitry and fault formats or dialer failed <br /> premise unit • Downloadable for indicators— Operates on loop start conditions(cannot be <br /> • FM approved remote programming eliminates the cause phone lines ahead of used for evacuation <br /> of most field calls. the building PBX purposes). <br /> • Can be used as a 60 hours of standby <br /> stand-alone or as a power Dual phone line system. <br /> add-on DACT interface Automatic <br /> self tests every 24 <br /> hours with report sent <br /> to central station <br />