Laserfiche WebLink
:'Product Report Manufacturer,, Metal Building Swpplies:, LL.C.: <br /> -800 E.-Donegan Ave: <br /> Kissimmee, FL 32531 <br /> (407)935-9714 <br /> ProductFlorida goofing <br /> Comp cant wit F ors a Bu mg Co a 2017 6 e Chapters 1504,1506,1507,1518,1523 - <br /> Compliant with Florida Product Approval Rule#61G20-3 <br /> Compliant Quality Assurance Program: Keystone Certifications *"Design Pressures Margin of Safety 2:1 <br /> FL4525.1 Product- 1.0 Nail Strip 24GA Non-Structural Application NON�HVIH1Z <br /> 16"wide roof panel 50ksi W tall rib w/slotted strip/snap lock Substrate:l5/32"APA plywood over max.24"o.c. <br /> supports spacing,W Minimum penetration through plywood.Corrosion Resistant Compliant Fastener Panel Slot:(1)#10-13 x <br /> 1"GP Pancake Type A.Corrosion Resistant Compliant Fastener Pan of Panel:(2)#10-11 x 1"Eclipse Head Type A. <br /> Underlayment:Self-adhered roofing underlayment min.40_mil_thickness. Minimum Slope shall comply with FBC 2017,6'h ed. <br /> Design Pressure". Fastener Spacing: <br /> -59.75 PSF Panel Slot @ 16"o.c. <br /> -101.0 PSF, Panel Slot @_6 W o.c. <br /> -153.5 PSF Panel Slot @ 6 W Panel Pan @ 12".o.c. <br /> FL 4525.2 Product: 1.5"Snap Locl( 24GA Standing Seam Non-Structural Application HVHz <br /> 16"wide roof panel 50ksi ' 1%"tall rib Substrate:l5/32"APA plywood existing over max.24"o.c.support spacing. <br /> FOR HVHZ:19/32"APA plywood new construction over supports @ 24"o.c. W min.penetration through plywood.Corrosion <br /> Resistant Compliant Fastener(2)#12-11 x 1 Pancake Type A. Clips:1500SNS,Fixed,18GA,3 W long, Valspar Fluropon <br /> Paint coating(optional)for metal panel.Installation per manufacturer's recommended details.Fire Barrier:'/.""Dens Deck"or <br /> approved equal.2:12 min.slope shall comply w/FBC 2017„6'"ed. USE RAS 133 FOR HVHZ. <br /> Design Pressure**: Fastener Spacing: <br /> -86.0 PSF 2 Fasteners per Clip @ 24"o.c. <br /> 408.5 PSF 2 Fasteners per Clip @ 22"o.c. <br /> -116.0 PSF_- 2 Fasteners per Clip @ 6"o.c. <br /> 36"wide roof panel 900 W tall rib @ 9"o.c.thru fastened.Substrate:Min.15/32"APA plywood existing construction <br /> over one layer of asphalt shingle(optional)over max.24"o.c.supports spacing,''/."min,penetration through plywood. <br /> FOR HVHZ 19/32"APA plywood new construction over supports @ 24"o.c.Corrosion Resistant Compliant Fastener#9-15 x 1 <br /> Woodgrip w/sealing washing or approved equal.Valspar Fluropon Paint coating(optional)For metal panel. Installation <br /> per manufacturer's recommended details.Fire Barrier:'/.""Dens Deck"or approved equal. 2:22 min.slope shall comply w/ <br /> FBC 2017,6t'ed.For slopes less than 3:22,lap sealant must be used in panel side laps. USE RAS 133 FOR HVHZ <br /> Design Pressure**: Fastener Spacing: <br /> -71.75 PSF 9"x 9"x 9"x 9"@ 24"o.c. <br /> 159.25PSF 6.5 x2.5 x6.5 x2.5 x6.5 x2.5 x6.5 x .5 @12 <br /> Product;;FL 452S.4 • ° • . Panel 26GA Over 1x4 Wood Purlins Non-Structural Application HVHI—i; <br /> 36"wide roof panel 80ksi W tall rib @ 9"o.c.thru fastened.Substrate:Min.1x4 No.2 SYP wood purlins over min. <br /> 15/32"APA plywood over max.24"o.c.supports spacing,1x4 wood purlins fastened to plywood w/8DX2 W Ring Shank nails <br /> at max.4"o.c.Corrosion Resistant Compliant Fastener#9-15 x 1 W Woodgrip w/sealing washing or approved equal,1/4" <br /> min.penetration through plywood.Valspar Fluropon Paint coating(optional).Installation per manufacturer's recommended <br /> details.Fire Barrier:''/•""Dens Deck"or approved equal. 2:12 min.slope shall comply w/FBC 2017,61'ed.For slopes less than <br /> 3:12,lap sealant must be used in panel side laps. USE RAS 133 FOR HVHZ <br /> Design Pressure**: Fastener Spacing: <br /> -106.75 PSF 9"x 9"x 9"x 9"@ 24"o.c. <br /> 464.25PSF 9"x9"x9"x9"@12"o.c. <br /> Product: Over Purlins Non-Structural Application, HvHz <br /> 36"wide roof panel 80ksi I W tall rib @12"o.c.thru fastened.Substrate:Min.2x4 No.2 SYP over 15/32"plywood <br /> existing construction over 24"o.c.supports spacing,1x4 wood purlins fastened to plywood w/8DX2 W Ring Shank nails at <br /> max.4"o.c.,min.W penetration through plywood. USE RAS 133 FOR HVHZ <br /> FOR HVHZ 19/32"APA Plywood New Construction.Corrosion Resistant Compliant Fastener#9-15 x 1-1/2"Woodgrip w/ <br /> sealing washer,or approved equal,''/•-14 x 7/8"lap screw w/sealing washer @ 24"o.c.in panel side lap.Valspar Fluropon <br /> paint coating(optional. Installation per manufacturer's recommended details.Fire Barrier:%""Dens Deck"or approved <br /> .equal. 2:12 min.slope shall comply w/FBC 2017,Wh ed.For slopes less than 3:12,lap sealant must be used in panel side laps. <br />