My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-90
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-90
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2022 12:46:43 PM
Creation date
3/2/2022 8:31:34 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-90
Building Department - Name
AMBROS,KATHRYN & ALVARO
Address
38104 9TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Enphase IQ 7 and IQ 7+ Microinverters . <br /> INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US <br /> Commonly used module pairings' 235 W--350 W+ 235 W-440 W+. <br /> Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules <br /> Maximum input DC voltage 48 V 60 V - <br /> Peak power tracking voltage 27 V-37 V 27 V-45 V <br /> Operating range 16 V-48 V, 16'V-60 V <br /> Min/Max start voltage 22 V/48 V 22 V/60 V <br /> Max DC short circuit current(module Isc) 15 A 15 A <br /> Overvoltage class DC port II II <br /> DC port backfeed current 0 A 04 <br /> PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; <br /> AC side protection requires max 20A per branch circuit <br /> OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter <br /> Peak output power 250-VA 295 VA <br /> Maximum continuous output power 240 VA 290 VA <br /> Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ - 208 V/ <br /> 211-264 V 183-229 V 211-264 V 163-229 V- <br /> Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) <br /> Nominal frequency 60 Hz 60 Hz <br /> Extended frequency range 47-68 Hz 47-68 Hz <br /> AC short circuit fault current over 3 cycles 5.8 Arms -5.8.Arms <br /> Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) <br /> Overvoltage class AC port III III <br /> AC port backfeed current 0 A 0 A <br /> Power factor setting 1.0 1.0 <br /> Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging <br /> EFFICIENCY @240 V @208.V @240 V @208 V <br /> Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% <br /> CEC weighted efficiency 97.0% 97.0% 97.0% 97.0°i <br /> MECHANICAL DATA <br /> Ambient temperature range -400C to+65°C <br /> Relative humidity range 4%to 100%(condensing) <br /> Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) <br /> Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). <br /> Adaptors for modules with MC4 or UTX connectors: <br /> PV2 to MC4:order ECA-S20-S22 <br /> PV2 to UTX:order ECA-S20-S25 <br /> Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) <br /> Weight 1.08 kg(2.38 Ibs) <br /> Cooling Natural convection-No fans <br /> Approved for wet locations Yes <br /> Pollution degree PD3 <br /> Enclosure Class II double-insulated,corrosion resistant polymeric enclosure <br /> Environmental category/UV exposure rating NEMA Type 6/outdoor <br /> FEATURES <br /> Communication Power Line Communication(PLC) <br /> Monitoring Enlighten Manager and MyEnlighten monitoring options. <br /> Both options require installation of an Enphase IQ Envoy. <br /> Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break <br /> disconnect required by NEC 690. <br /> Compliance CA Rule 21 (UL 1741-SA) <br /> UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B; <br /> CAN/CSA-C22.2 NO.107.1-01 <br /> This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and <br /> NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC <br /> and DC conductors,when installed according manufacturer's instructions. <br /> 1.No enforced DC/AC ratio:See the compatibility calculator at https//enphase com/en-us/support/module-com atR ibility. <br /> 2.Nominal voltage range can be extended beyond nominal if required by the utility. <br /> 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. <br /> To learn more about Enphase offerings,visit enphase.com u EN PHASE. <br /> @ 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. <br /> 2018-05-24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.