Laserfiche WebLink
! 4 <br /> -Snow Load 21-30,psf <br /> Modules in Landscape <br /> 'Wind Speed Exposure 2:12<Roof Pitch<6:12, 7:12.<Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone.3 Zone .1 Zone 2 , Zone 3• . <br /> B 93 59 <br /> 85 mph• 110 mph. C 67 42 <br /> D .96 56 35 <br /> B 85 54 <br /> -90 mph 115 mph C 104 61 38 <br /> D_ 88 51 32 <br /> B 72 45 <br /> 100 mph 126 mph ' C 88 51 32 <br /> D 74 43 27 57 47 . <br /> B 98 57 36 <br /> 110 mph 140 mph C 70 41 26 66 54 .54 <br /> D 59 34 22 56' 46 46 <br /> B 85 50 31 66 '66 <br /> 120 mph 150 mph C 61 36, 22 58 47 47 <br /> D. 51 30 19 49 40 40 <br /> Notes: <br /> Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing In inches for pullout forces only on EcoFasten Solar standoff, <br /> however the designer must round down to meet appropriate rafter spacing <br /> 2:)Maximum allowed spacing approved by EcoFasten Solar Is 72" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results). <br /> 4.)Includes additional factor of safety of.1.5 for lag pullout capacity <br /> 5-)Values based on a maximum width of 40" <br /> 6.)Based on Risk Category 11(ASCE 7-10)'structures less than 30 feet in height <br /> 7.)All adjustment factors.are set to 1.No site specific engineering is Included In this table <br /> Snow Load 21-30. psf. <br /> Wind Speed Exposure 2:12<Roof*,Pitch<.6:12 7:12<Roof Pitch<.12:12 <br /> ASCE 7-05'ASCE,7-10 Cate o Zone 1 Zone 2 Zone 3 Zone 1 Zone 2• Zone 3 <br /> 85 mph 110 mph C 65 k 38 24 <br /> - _ D_ �55. _.3? 20 <br /> B 49 30' <br /> 90 mph. . 115 mph C 59 35 22 <br /> D 50 29 _18 38 38 <br /> 41---7 y 26� <br /> 100 mph 125 mph C 50 29 18 vl 39 <br /> D 42 �`6, 15 . . �.0 -'�;�32 ,t.f 32 <br /> B 56 33 20 <br /> 110 mph 140 mph C 40 23 14 38 31- 31 <br /> D 34 19 12 32 .26 26 <br /> g_ _ 37 t" - 37 <br /> 120 mph 150 mph w G 35 20 12 .33 27 27�. <br /> D 29 17 10 28 22 2Z, <br /> Notes: <br /> -Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing In Inches for pullout forces only on EcoFasten Solar-standoff <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" <br /> 3.)Maximum allowed standoff capcity=547#.(per testing results) <br /> 4.)Includes additional factor of safety of-1.5 for lag pullout capacity <br /> 5.):Values based on a.maximum module length of70" <br /> 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height. <br /> 7.)All adjustment factors are set to 1.No site specific engineering isincluded in this table <br /> www.ecofastensoiarcom info@ecofastensolaccom 877-859-3.947 9 <br />