Laserfiche WebLink
R O C K- 1-T S J- S Te f'1'1 4.0 <br /> SYSTem sPeclFicaTions <br /> Max No.of Panels .300 Modules per ground lug Materials 300 Series Stainless, <br /> 6000 Series Aluminum <br /> Max System Voltage 1000VDC Coating BlackAndodization/Mill Finish <br /> Class A Fire Rating, With UL7703Type 1 Rated Lug Spedfications Bumdy CL50.1TN Ground Lug <br /> Modules;see note below. (UL Listing#KDER E9999) <br /> Leveling Range 34" Ground Wire 14 AWG-4 AWG Copper <br /> Per above Lug spec. Ground Wire <br /> Rock-It Slide Comp.Range 3" Max Module Size .64.96"(1650mm)x <br /> Rock-it Slide Mle 7" 39.05'(992mm)x 2"(50mm) <br /> Min/Max Roof Slope 1/2.12/12:12 Max Downforce/Uplift Rating 45 PSF <br /> Max Anchor Spacing(35mm/40mm) 72" Rock-It Mount Load Rating 547lbs with Single 5/16'Lag 3.0 <br /> Max Anchor Spacing(32mm) 48' Safety Factor <br /> Skirt Box QTY 6 units Slide Fastening Hole 5/16"diameter <br /> Mount Box QTY -12 units Module Cantilever Maximum cantilever is 1/3 <br /> Rock-It Slide Box QTY 50 units bracket spacing <br /> Coupling Box QTY 12 units Warranty 20Year Material and Workman <br /> ship <br /> Codes:National.Efectric Code;ANSVNFPA 70,NEC 250,NEC 690,IRC,IBC <br /> Standards:UL 2703:First Edition,UL 1703 <br /> I mCascenSolar. <br /> �.eOr45itlSOI3f ROCJt-fT SYSTEM <br /> "M IDCODE:GOT-QZ-2016 <br /> [CMfOM6T0 UL ZT0.1 GCXWWdSTDUL2703 <br /> V1N 4lT.MG:SE[t.SiMUO.�Y <br /> .ac.. "1WLL4{OPI"MfA1C1G5 <br /> MWIDIVtOTiYDG1II12 <br /> nA <br /> The EcoFasten Solar Rock-It System is a rooftop PV racking system consisting of 6000 Series Aluminum and 300 Series <br /> Stainless.Steel components.The Rock-It System Includes the rack components but does not Include the PV panels, <br /> inverters or electrical-components.The PV modules to be used with Rock-It shall be certified under UL 1703.The <br /> system shall be used on steep slope roofs mounted over a Class Afire rated roofing material and attached to the roof <br /> structure using:5/16".diameter,minimum 4"long 300 series Stainless Steel lag bolts with minimum thread <br /> embedment depth of 21/2"into the roof structure. <br /> Periodic re-inspection for loose components <br /> The system is subject to as required by the PV module manufacturer or.by the Authority.Having <br /> Jurisdiction.Re-inspection;as required,should include evaluation of any loose components or loose fasteners.All <br /> .loose components and fasteners should be,secured.in accordance with these instructions:The system should also be <br /> evaluated for any evidence of corrosion.Any corrosion should-be removed:Any affected part should be.cleaned or <br /> replaced in accordance with these instructions. <br /> I&4 A <br /> ®O'EcoFasten S®1a�r® <br /> -www ecofastensolar com info@ecofastensolar com 877-859-3947 15. <br />