Laserfiche WebLink
; <br /> 23. Tamper-Resistant Receptacles in accordance with 406.11 of the.2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots.shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25-. R403.5.3Hot waier.'pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping-14 inch (1.9.1 mm)and larger in-nominal.diameter.. <br /> Piping serving more than.one dwelling unit: <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to.a distribution manifold:. . <br /> Piping.located under.a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.-Blower door test shall be provided before C.O: <br /> 26. A copy of the enem cacls shall be.with peen:it at all times. <br /> 2Z Copy of real insulation Yeport shall-be provided ivith Permit before rinaL <br /> 28:No fence. Pool or screen enclosure :is issued with ahis-pern:ii"` <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 0"Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />