My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-126
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-126
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 8:59:59 AM
Creation date
3/2/2022 8:59:57 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON INC
Building Department - Doc Type
Permit
Permit #
20-126
Building Department - Name
DR HORTON INC
Address
7757 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q� D <br /> x <br /> Single Family Dwelling <br /> Plan Review Comments <br /> I. F.F.E: shall be a ininimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C- <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4.. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R..O:W. use permit: All 4 sides of driveway thrit the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> T All-property markers shall be uncovered.and marked at time of first inspection. <br /> 8: All A.D.A.requirements shall be met: <br /> 9-. No electric,.plumbing;mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.-BOAC. <br /> 13. Foundation supports for A/C units-shall be raised at least 3" above finished grade. M1308:1 - <br /> 14. Return air it! all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing reguirenrients are to be in accordance-with R308.4 of the F.B.C. <br /> 17. All means of egress are.to be_in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum,board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an-attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22, All 2016 N.E.C. Codes will be enforced: <br />
The URL can be used to link to this page
Your browser does not support the video tag.