My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-126
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-126
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 8:59:59 AM
Creation date
3/2/2022 8:59:57 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON INC
Building Department - Doc Type
Permit
Permit #
20-126
Building Department - Name
DR HORTON INC
Address
7757 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> LOT 4, BLOCK 10, ZEPHYR LAKES SUBDIVISION PHASES 1A, 2A, 28, AND 4A <br /> AS RECORDED IN PLAT BOOK 80, PAGE(S) 37-48, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br /> PI <br /> Line Table <br /> Una/ Directlon Length <br /> L1 S0034'52-W 40.00' <br /> 'd•O �3 <br /> 0 o i LOT 5 I I Z2 <br /> m BLOCK 10 1 Im iz <br /> I 1` 1" — 30, <br /> pro NIP I GRAPHIC SCALE <br /> _•— — 9 S89'25'08"E 115.00' ss I o 15 30 <br /> 5'D&AE ut� _ .>- <br /> LLJ — 33.3'---- — — — — — :— Q <br /> 54.7' —27.0'T" I O <br /> 10 <br /> J l �° o <br /> o IZ <br /> J Q 00 g ~ 71 <br /> i. 5rL <br /> "p F a <br /> 77 <br /> --- 33.3'-- ------ —9• ---- — 320'_`I" O <br /> to <br /> 5'D&AE I I -- z m <br /> N89'25'08"W 115.00' N8925.06'W <br /> Sq dry\ 25.00' Nm <br /> A � <br /> z <br /> o I LOT 3 I $� <br /> tO BLOCK 10 I N ' <br /> :Y I I --I <br /> �� I <br /> m. <br /> PI <br /> ON LOT CALCULATIONS FLAT BOUNDARY <br /> LOT — 4.600 SQ. FT. <br /> LIVING AREA = 1.239 SQ. FT. <br /> GARAGE 248 SQ. FT. <br /> ENTRY = 21 SO. FT. <br /> LANAI = 0 SO. FT. <br /> PATIO = 80 SQ. FT. <br /> DRIVEWAY 256 SO. FT. <br /> A/C PAD = 12 SQ. FT. <br /> WALKWAY = 24 SQ. FT. <br /> IMPERVIOUS = 41% <br /> = 1880 SQ. FT. <br /> SOD = 2,720 SQ. FT. <br /> OFF LOT CALCULATIONS <br /> RIGHT OF WAY 480 SQ. FT. <br /> DRIVE APRON 77 SQ. FT. <br /> PREPARED FOR: PUBLIC S/W = 200 SQ. FT. <br /> n* y'�;�f ;;��;;���,,,, SOD = 203 SQ. FT. <br /> U•AE•HUIif�UN'Fi E.' TOTALS <br /> s?#^LCCF'F�tcB�Ca'Et AREA 5,080 SO. FT. <br /> DRIVEWAY m 333 SQ. FT. <br /> BUILDING SETBACKS SIDEWALK = 224 SO. FT. <br /> SOD 2,923 SO. FT. <br /> FRONT: 20' <br /> GARAGE: 25' <br /> REAR: 15' <br /> SIDE: 5' <br /> SIDE STREET: 15' <br /> NOTES: LEGEND: <br /> 1. PROPOSED ELEVATIONS SHOWN HEREON ARE — BUILDING SETBACK LINE PI POINT OF INTERSECTION <br /> BASED ON THE APPROVED ENGINEERING PLANS PC POINT OF CURVATURE <br /> PREPARED BY HAMILTON ENGINEERING & — CENTERLINE PT POINT OF TANGENCY <br /> SURVEYING INC.. —— —— RIGHT OF WAY LINE RP RADIUS POINT <br /> PRC POINT OF REVERSE CURVATURE <br /> 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCP PERMANENT CONTROL POINT <br /> DATUM. TYP TYPICAL <br /> ==> PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES r:1pi CONCRETE (P) PER <br /> CA <br /> LCULATED <br /> PLATED <br /> ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF 0 (c) PLAT BOOK <br /> THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PB Pas PAGES <br /> OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING s/W SIDEWALK SO. FT. SQUARE FEET <br /> DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.EM.A. FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP <br /> NAVD NORTH AMERICAN VERTICAL DATUM <br /> D&UE DRAINAGE&UTILITY EASEMENT <br /> THIS IS NOT A SURVEY DE DRAINAGE EASEMENT(PUBLIC) <br /> THIS IS A PLOT PLAN ONLY LIE UTILITY EASEMENT(PUBLIC) <br /> DdeAE DRAINAGE&ACCESS EASEMENT <br /> FLOOD NOTE: SURVEYOR NOTES: <br /> I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO293F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> DATED 09/26/2014. AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT <br /> APPEARS TO LIE IN ZONE "X", AREAS,DETERMINED TO BE OF WAY, RESTRICTIONS OF RECORD WHICH <br /> OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. THE MAY AFFECT THE TITLE OR USE OF THE LAND. <br /> SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. <br /> AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. <br /> BEARING BASIS: A5hA 3. NOT VALID WITHOUT THE AUTHENTIC <br /> BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF BROAD ELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> POINTE DRIVE BEING S0034'52'W PER PUT. A�n E�' �,�N SELECTRONIC SEAL OF A URVEYOR AND MAPPER.FLORIDA LICENSED <br /> (FIELD DATE:) REVISED: <br /> SU RV EY I N G stw Digitally signed by James W.Boleman <br /> SCALE: 1' 30 FEET a;.H•BT DN:cn=James W.Boleman, <br /> 4& MAPPING INC. <br /> o=American Su vey ng&Mapping, <br /> APPROVED BY: '� ''�'" Inc•ou=H8, <br /> CERTIFICATION OF AUTHORIZATION NUMBER LB16393 rc ,4 email=JBoleman@asmcorporate.com, FOR <br /> 3191 MAGUIRE BOULEVARD, SUITE 200 ".e+ c=us <br /> 190901 LOT 4,BLOCK 10 THE <br /> JOB NO. ORLANDO. FLORIDA 32803 �+•'�• Date:2019.0914165227-04'00; FIRM <br /> (407) 426-7979 DRAWN BY. DSB PLOT PLAN 09-20-19 ZA WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE <br />
The URL can be used to link to this page
Your browser does not support the video tag.