Laserfiche WebLink
p <br /> 4 <br /> i <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation an_ d an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the.F.B.C. <br /> 3: Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. .Driveways require a R.O:W. use permit. All 4 sides_ of driveway thru the sidewalk shall_have <br /> expansion material... <br /> 6. All setbacks shall be met. <br /> -7: All property markers shall be uncovered.and marked at time of first inspection. <br /> 8: All A.D.A.requirements shall-be met: <br /> 9: No electric,plumbing,. mechanical, or.framing shall,.be covered without an inspection.and <br /> Approval first: <br /> 10.. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): <br /> I L Appliances shall not be installed in a location where subject to mechanical damage unless' <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12. Water heaters.shallcomply with section P607.3 of the F:B.C: <br /> 13. Foundation supports for A/C units:shall be raised at least 3" above finished grade. MI308:1. <br /> 14. Return air in all bedrooms: F.B:C. M1620A <br /> 15. Smoke detectors are to be,installed in'accordance with R313:1 of the F.B.C. <br /> 16. All glazing requirenients are to be.in accordance.with R308.4 of the F.B.C, <br /> . <br /> 17. All means.of egress are to be In accordance with R311 of the F.B.C.. <br /> 18. "Green.gypsum.board" shall not be used as a backer in showers or tubs. R702A.2 F.B.C. <br /> 19: Combination-type AFO breakers are required at all locations requiring an AM type breaker. <br /> 20. Carbon monoxide.alanns will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground:plumbing And electric. <br /> 2I All 2016 N.E.C. Codes will be enforced. <br />