Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the.2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots_ shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25; R403.5.3Hot water pipe.insulation, . <br /> Insulation for hot water pipe with'a minimum thermal resistance (R-value) of R-3 shall tie-applied to the <br /> following:. <br /> Piping.31.inch (1.9.1 mm)and larger in.nominal diameter. <br /> Piping.serving more than one dwelling unit. <br /> Piping located outside the conditioned space:. <br /> Piping from the water heater to a distribution manifold. <br /> Piping:located under a floor slab. . <br /> Buried in piping,. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25: Blower door test shall be provided before C.O: <br /> 26. A coov of the-energy cacls shall be with permit at all times <br /> 27.. Copy of final insulation report shall be provided with permit before fna� <br /> 28. No fence,pool or scr.een enclosure as issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />