My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-139
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-139
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 9:10:25 AM
Creation date
3/2/2022 9:10:24 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON INC
Building Department - Doc Type
Permit
Permit #
20-139
Building Department - Name
DR HORTON INC
Address
8133 WHEAT STONE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> LOT 46, BLOCK 3, ZEPHYR LAKES SUBDIVISION PHASES 1A, 2A, 2B, AND 4A <br /> AS RECORDED IN PLAT BOOK 80, PAGE(S) 37448, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br /> Curve Table <br /> Curve# Length Radius Delta Chord Bearing Chord <br /> C1 33.30' 1211.00' 134'31' N66'59'16"W 33.29' 0 <br /> qC <br /> C3 258.56' 1186.00' 1229'27' N74`01'I5"W 256.OW ORANA/G'e Fl qRe& <br /> C4 32.66 1186.00' 1,3W31' N66*59'16"w 32.61' \• � T�pU�� I <br /> eUC) <br /> ro <br /> Line Table fig. 42 ' 40 i <br /> Una# Direction Length 6<OC 1" = 30' <br /> L1 Nss'12'o0"w 1s.ts' I �l� 4OT 43 k 3 GRAPHIC SCALE <br /> L2 S67'42'40"E 36.75' sOCk46 0 15 30 <br /> L3 S6612'00"E 16.16' R4/ry4SQ Fr1841 <br /> e40 3 agar /. O <br /> O McRopq. <br /> Q) yam. A,/4%y q / <br /> M <br /> 4OT <br /> �3 04o�k S <br /> 3 <br /> pp�� 00 <br /> o.. m <br /> 00 <br /> cp <br /> ON LOT CALCULATIONS <br /> LOT = 6.438 SO. FT. <br /> 10, '16,p:;;`.;• // LIVING AREA = 2,034 SQ. FT. <br /> �O• \ `' `•' /� GARAGE = 458 SQ. FT. <br /> F ENTRY = 28 SQ. FT. <br /> �$/ �.,,• LANAI = 218 SQ. FT. <br /> \ "y� y PATIO = 0 S . FT. <br /> DRIVEWAY = 430 SO. FT. <br /> C�x / [• A/C PAD = 12 SQ. FT. <br /> WALKWAY = 36 SO. FT. <br /> 4. <br /> C? C, _ . IMPERVIOUS = 50% <br /> = 3216 SO. FT. <br /> V "Oj, SOD = 3,222 SO. FT. <br /> S FqT PtPr < OFF LOT�D NS <br /> RIGHT OF WAYS=0641 SQ. FT. <br /> O �O ST DRIVE APRON = 152 SO. FT. <br /> PREPARED FOR: F pR/�q"HF Hg <br /> 4Y PUBLIC s/w = 247 SQ. Fr. <br /> SOD = 242 SQ. FT. <br /> iD'R'HUIII�N � gjOyT RI \\ TOTALS <br /> y eg g:g d6d t3#* Op W4 \ AREA = 7,079 SO. FT. <br /> DRIVEWAY = 502 SO. FT. <br /> BUILDING SETBACKS SIDEWALK = 283 SO. FT. <br /> FRONT: 22' SOD = 3.464 SO. FT. <br /> GARAGE: 27' <br /> REAR: 13' <br /> SIDE: 5' <br /> SIDE STREET: 15' <br /> NOTES: <br /> LEGEND: <br /> 1. PROPOSED ELEVATIONS SHOWN HEREON ARE —• —• — BUILDING SETBACK LINE PI POINT OF INTERSECTION <br /> BASED ON THE APPROVED ENGINEERING PLANS PC POINT OF CURVATURE <br /> PREPARED BY HAMILTON ENGINEERING & —— CENTERUNE PT POINT OF TANGENCY <br /> SURVEYING INC.. — ——'— RIGHT OF WAY LINE RP RADIUS POINT <br /> 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PRC POINT OF REVERSE CURVATURE <br /> PCP PERMANENT CONTROLL POINT <br /> DATUM. TYP TYPICAL <br /> PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES z..i. CONCRETE (P) PER PLAT <br /> CALCULATED <br /> ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (C PLAT BOOK <br /> THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PAGES <br /> OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SO. FT. SQUARE FEET <br /> DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP <br /> NAVD NORTH AMERICAN VERTICAL DATUM <br /> D&UE DRAINAGE&UTILITY EASEMENT <br /> THIS IS NOT A SURVEY DE DRAINAGE EASEMENT <br /> THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT(PUBLIC) <br /> FLOOD NOTE: SURVEYOR NOTES: <br /> I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO293F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> DATED 09/26/2014,AND FOUND THE SUBJECT PROPERTY APPEARS TO LAND SHOWN HEREON FOR EASEMENTS, RIGHT <br /> UE IN ZONE'X%AREAS DETERMINED TO BE OUTSIDE THE 0.2%ANNUAL OF WAY, RESTRICTIONS OF RECORD WHICH <br /> CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO GUARANTEES AS TO MAY AFFECT THE TITLE OR USE OF THE LAND. <br /> THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT <br /> FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> LOCATED EXCEPT AS SHOWN. <br /> BEARING BASIS: A5hR <br /> BEARINGS SHOWN HEREON ARE BASED ON THE NORTHWESTERLY LINE 3. NOT VALID WITHOUT THE AUTHENTIC <br /> OF LOT 46 BEING N22'13'29'E,PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> (FIELD DATE:) REVISED: <br /> A M E FR I C A N SURVEYOR ANDAMAPPER FLORIDA LICENSED <br /> SCALE: 1"—30 FEET SURVEYING �:f.•^��� .Dtr-u;a9�dtfbn)dalbnaMoeman <br /> 8cM A P P I N G INC. <br /> �AMflUCRN SDNVEYP G&ANPVING <br /> APPROVED BY: is 1NC -3amaawed„nan. - <br /> CERTIFICATTON OF AUTHORIZATION NUMBER LB16393 emmi=jmN,nanwvnm�—m FOR <br /> 3191 MAGUIRE BOULEVARD, SUITE 200 '••` '+' Da r)O1003.131633A)-0aUp <br /> JOB NO. 190901 LOT 48, BLOCK 3 ORLANDO, FLORIDA 32803 THE <br /> FIRM <br /> (407) 426-7979 DATE <br /> DRAWN BY. RMB PLOT PLAN 05-04-20 JCM �•AMERICANSURVEYlNGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 <br />
The URL can be used to link to this page
Your browser does not support the video tag.