My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-204
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-204
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 9:54:05 AM
Creation date
3/2/2022 9:53:57 AM
Metadata
Fields
Template:
Building Department
Company Name
SF ZEPHYR COMMONS LP
Building Department - Doc Type
Permit
Permit #
20-204
Building Department - Name
SF ZEPHYR COMMONS LP
Address
7910 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section <br /> # Mechanical Rough-In Inspection Complies? Comments/Assumptions <br /> & Req.ID <br /> C403.2.9. ;Duct insulation is protected from ;❑Complies <br /> 1.2 damage but not limited to the ❑Does Not <br /> [ME80]2 jfollowing: 1. Insulation exposed to <br /> i weather is suitable for outdoor ❑Not Observable <br /> service. Cellular foam insulation is ❑Not Applicable <br /> {protected or painted with a coating <br /> that is water retardant and provides <br /> shielding from solar radiation.2. <br /> ;Insulation covering cooling ducts <br /> 'located outside the conditioned space <br /> is vapor retardant located outside the <br /> insulation, all penetrations and joints <br /> ;of which shall be sealed. <br /> C403.2.9. ;Additional insulation with vapor ❑Complies <br /> 1.3 )'barrier is provided where the ❑Does Not <br /> [ME81]2 ;minimum duct insulation requirements;❑Not Observable; <br /> of Section C403.2.9.1.1 are <br /> determined to be insufficient to ❑Not Applicable <br /> prevent condensation, j <br /> C403.2.13 t Unenclosed spaces that are heated ;❑Complies <br /> [ME71]2 ;use only radiant heat. UDoes Not <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C403.2.3 'HVAC equipment efficiency verified. ;❑Complies ;See the Mechanical Systems list for values. <br /> [ME55]2 UDoes Not <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C403.2.9. Ducts, air handlers,filter boxes, ;❑Complies <br /> 3 1 building cavities, mechanical closets ;❑Does Not <br /> [ME10]2 ;and enclosed support platforms that <br /> sform the primary air containment ;❑Not Observable <br /> passageways for air distribution �❑Not Applicable <br /> systems are sealed in accordance with! <br /> ;the applicable criteria of this section <br /> and Table C403.2.9.2. <br /> C403.2.9. j Cavities in framed spaces are not ;❑Complies <br /> 4 used to deliver air from or return air to UDoes Not <br /> [ME78]2 ;the conditioning system unless they <br /> contain an air duct insert which is :❑Not Observable: <br /> insulated in accordance with Section t]Not Applicable <br /> C403.2.9.1 and constructed and <br /> 3sealed in accordance with the <br /> requirements of Section C403.2.9.2 <br /> appropriate for the duct materials <br /> used. <br /> C403.2.9. Air distribution systems are sized and ❑Complies <br /> 5 ;designed in accordance with ❑Does Not <br /> [ME76]2 recognized engineering standards. <br /> Refer to section details. ❑Not Observable <br /> ❑Not Applicable <br /> C403.2.9. jAir-handling units not installed in ;❑Complies <br /> 6 I attics of commercial buildings. UDoes Not <br /> [ME77]z i <br /> i '❑Not Observable 1 <br /> ❑Not Applicable <br /> 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) <br /> Project Title: Planet Fitness-Zephyrhills, FL Report date: 04/09/20 <br /> Data filename: C:\Users\msaarem\Dropbox\Production\_2020.013 Planet Fitness-Zephyrhills, FL Mar\20.013 Page 10 of 18 <br /> Planet Fitness 7 Zephyrhills, FL-ComCheck.cck <br />