Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> .24. In accordance with the Land Development Code, lots.shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot.waterpipe insulation <br /> Insulation for hot:water pipe with a minimum thermal resistance.(-R-value) of R-3 shall.be applied to the: . <br /> followin <br /> Piping�/: inch,( .91 mm) and larger in.nominal diameter. <br /> Piping;serving more than one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping from the::wat&heater to.a distribution manifold-. . <br /> Piping,located under a floor slab: <br /> Buried in piping,: <br /> .Supply and return piping in recirculation systems other than demand recirculation_ systems. <br /> 25: Blower door test shall be provided before CoO. <br /> 26.A cony of the energy cacls shall be with permit at all times <br /> 27. Copy of-Xi insulation report-shall be Provided with pernut before final <br /> 28 No fence, pool onscreen enclosure :is issued with:thispermiz <br /> F.F.E.-Finished Floor Elevation <br /> F.B.0 •Florida Building Code 60'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=.Americans with Disabilities Act. N.E.C.-National Electric.Code (2016) <br />