Laserfiche WebLink
21 Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 ME <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hof water pipe insulation <br /> insulation for hot water pipe with a minimum thermal-resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 3/, inch (19.1 mm)and larger in.nominal diameter.. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space.. <br /> Piping from the matey heater to a distribution manifold <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25: Blower door test shall be provided before C.O: <br /> 26.A cony of the enerzy.cacls shall be with permit at all times <br /> 27. Cony of final insulation report shall be provided with permit before final <br /> 28 No fence,-pool or screen enclosure'.is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6.h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />