Laserfiche WebLink
i <br /> ' 1 <br /> D <br /> Q <br /> i <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall be a minimum of-8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to.comply with R401:3 of the F.B.C: <br /> 3. Compaction test required if 24" or more of fill.dirt is brought in at any.one.place. <br /> 4: Tie in survey required before,pouring concrete. <br /> 5. Driveways require a R..O M. use permit. All 4 sides_ of driveway thru the sidewalk shall have <br /> expansion material.. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered.and marked at time:of first inspection. <br /> 8: All A.D:.A.requirements shall be.met: <br /> 9: No electric,.plumbing, ineclianical, or.framing shall be:covered with an inspection and <br /> approval first. <br /> 10: All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). <br /> 11.Appliances,shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F;B:C <br /> 12. water heaters shall comply with section P607.3 of the F.B.C. <br /> -13:-Foundation supports for A/C units.shall.be raised at least 3"above finished grade. M1308.:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be- installed in accordance with.R313:1 of the.F.B.C:. <br /> 16. All glazing requirements are to be in accordance with R308A.of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. ``Green gypsum.board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon*monoxide alarms will be required iri new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21..All plumbing,mechanical, and electrical shall be separate:from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />