Laserfiche WebLink
23. Tanker- Resistant.Receptacles in accordance with 406.11 ofthe 2016 N.E:C <br /> 24. In accordance with the Land Development Code,lots,shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water pipe insulation <br /> Insulation for liot water'pipe with a minimum thermal resistance.(R-value) of R-3 shall.be applied-to the <br /> following: <br /> Piping /; inch (19:1 mm) and larger in.nominal diameter: <br /> Piping serving more than one dwelling unit: <br /> Piping located.outside the conditioned space: <br /> Piping from the:waterheater to a distribution manifold:_ <br /> .Piping:located under.a floor slab. <br /> Buried in piping. <br /> Supply and returnpiping <br /> in recirculation systems other than demand recirculation systems. <br /> 25: Blower door test shall be provided before C.O: <br /> 26.A copy bt the energy cacls shall be:wit <br /> h at all dines: <br /> 27. Copy of final insulation report shall-be provided with permit before final <br /> 28. No-knee,-Pool or'screen"enclosure :is issued with:this.permit. <br /> F.F.E.-Finished_ Floor Elevation <br /> F.B.C-.Florida Building Code 6t.'Edition <br /> R.O.W.-Right of Way <br /> A.D:A.=:Americans With Disabilities Act. N.E.C.-National Electric.Code(2016) <br />