Laserfiche WebLink
9 <br /> 23. Tamper-Resistant Receptacles in accordance with 406.11 of the.2016 N.E.0 <br /> .24. In accordance with the Land Development Code,lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> .25-. R403.5.3Hot Water.pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall.be applied to the <br /> following: <br /> Piping inch (19.1 mm) and larger in, nominal diameter, <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space.,. <br /> Piping from the water heater to.a distribution manifold: <br /> Piping located under a floor'slab.' <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25:Blower door test shall be provided before C.O. <br /> .26.A copy ofthe enemy cacls shall be with permit at all times <br /> 27. Copt/of final insulation report-shall be provided with permit before fnaL <br /> 28 No fence,-pool or screen'enclosure is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> RB.0 Florida Building Code 6U'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric.Code(2016) <br />