My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-288
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-288
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 11:27:28 AM
Creation date
3/2/2022 11:27:26 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-288
Building Department - Name
DUQUE,CALVIN & LINDSEY
Address
37625 8TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> WALLS <br /> Adjacent Cavity Width Height Sheathing Framing Solar Below <br /> Frnt 10 Wall Type Space p_N/=,,,e Et In Et In Aren RA/ahle E-mr-flon Abso, <br /> I N Exterior Frame-Wood House 19 47 8 10 0 476.7 ft2 0 0.25 0.3 0 <br /> -2 E Exterior Frame-Wood House 19 53 4 10 0 533.3 ft2 0 0.25 0.3 0 <br /> - 3 S Exterior Frame-Wood House 19 43 4 10 .0 433.3 ft2 0 0.25 0.3 0 <br /> 4 W Exterior Frame-Wood House 19 29 4 10 0 293.3 ft2 0 0.25 0.3 0 <br /> -5 W Garage Frame-Wood House 13 24 0 10 0 240.0 ft2 0 0.25 0.01 0 <br /> -6 S Garage Frame-Wood House 13 4 4 10 0 43.3 ft2 0 0.25 0.01 0 <br /> DOORS <br /> V # Omt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> I W Insulated House None .46 3 7 21 ft2 <br /> 'WINDOWS <br /> Orientation shown is the entered,Proposed orientation. <br /> Wall Overhang <br /> # Omt ID Frame Panes NFRC U-(`actor SHGC Imp Area Depth Separation int Shade Screening <br /> I N I TIM Low-E Double Yes 0.33 0.25 N 24.0 ft2 '8ft0in I ft0in None None <br /> 2 N I TIM Low-E Double Yes 0.33 0.25 N 24.7 ft2 8 ft 0 in I ft0in Drapestblinds Exterior 5 <br /> 3 N I TIM Low-E Double Yes 0.33 0.25- N 6.0 ft2 8 ft 0 in I ft0in None None <br /> 4 E 2 TIM Low-E Double Yes 0.33 0.25 N 24.0 ft2 1 ftoin 5ft0in None None <br /> 5 E 2 TIM Low-E Double Yes 0.33 0.25 N 15.0 ft2 1 ftoin 5ft0in Drapes/bfinds Exterior 5 <br /> 6 E 2 TIM Low E Double Yes 033 0.25 N 22.1 ft2 1 ft4in 1 ft6in Drapes/blinds Exterior 5 <br /> 7 S 3 TIM Low-E Double Yes 0.33 0.25 N 24.0 ft2 5 It 0 in 1 ft0in None None <br /> 8 S 3 TIM Low-E Double Yes 0.33 0.25 N 23.4 ft? I ft 4 in I ft6 in Drapesiblinds Exterior 5 <br /> 9 S 3 TIM Low-E Double Yes 0.33 0.25 N 23.4 ft2 1 ft 4 in 5 ft 0 in Drapesiblinds Exterior 5 <br /> 10 S 3 TIM Low-E Double Yes 0.133 0.25 N 31.8 ft2 5 ft 0 in 1 ft0in Drapes/blinds Exterior 5 <br /> 11 W 4 TIM Low-E Double Yes 0.33 0.25 N 31.8 ft2 1 ft4in I ft0in Drapes/blinds Exterior 5 <br /> 12 W 4 TIM Low-E Double Yes 0.33 0.25 N 6.0 ft2 1 ft 4 in I ft0in None None <br /> 4-ARAGE <br /> Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 576 ft2 576 ft2 64 ft 8 ft <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000445 2527 138.73 260.9 .1781 7 <br /> 4/24/2020 4:50 PM EnergyGauge@)USA 6.0.02(Rev.1)-FlaRes2017 FBC;6th Edition(2017) Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.