My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-288
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-288
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 11:27:28 AM
Creation date
3/2/2022 11:27:26 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-288
Building Department - Name
DUQUE,CALVIN & LINDSEY
Address
37625 8TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job.- R0420165 <br /> +�+ W Fightsoft, Date: Apr 23,2020 <br /> Entire House By: MKc <br /> GL Steve Construction <br /> 37651 8th Ave,ZepFry Is,FL 33-142 <br /> Project • . • <br /> For. Calvin and Lindsey Doque <br /> 8thAve,Zephyrhills,FL 33542 <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 24801 Btuh Entering coil DB: 83.1°F <br /> Outdoor design WB: 77.2°F Latent gain: 5096 Btuh Entering coil WB: 65.8°F <br /> Indoor design DB: 75.0'F Total gain: 29897 Btuh <br /> Indoor RH: 50% Estimated airflow: 1140 cFm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SplitASHP <br /> Manufacturer. 3 Ton Goodman Mfg. Model: GSZ160361 B+ASPT37C14A <br /> Actual airflow: 1140 cfm <br /> Sensible capacity: 24966 Btuh 101%of load <br /> Latent capacity: 9234 Btuh 181%of load <br /> Total capacity: 34200 Btuh 1141/oof load SHR: 730/c, <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 20301 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.00F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SplitASHP <br /> Manufacturer. 3 Ton Goodman Mfg. Model: GSZ160361 B+ASPT37C14A <br /> Actual airflow: 1140 cfm <br /> Output capacity: 35000 Btuh 172%of load Capacity balance: 29 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer. Model: <br /> Actual airflow: 1140 cfm <br /> Output capacity: 10.0 kW 168%of load Temp.rise: 44 OF <br /> Meets all requirements ofACCA Manual S. <br /> r wrightsolFt" 2020-Apr-24163500 <br /> ,..•: .„,...w.,, RigttStiL-@Uriversa1201919.0.18 RSU07440 Page 1 <br /> ACC _v60 <br /> ri-Duque-L-E-MailirgC4vd?R0420165.rup Calc=MJ8 FrortDooriaces S <br /> ■ <br />
The URL can be used to link to this page
Your browser does not support the video tag.