Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. Iri accordance with.the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water pipe insulation . <br /> Insulation for hot.water pipe with a minimum thermal resistance(R-value) of R-3 shall be. applied to the <br /> following: <br /> Piping�/:inch (19.1 mm)and larger in nominal diameter. <br /> Piping,serving more than:one dwelling unit. <br /> Piping located outside the"conditioned space: <br /> Piping from the water heater to a distribution manifold. <br /> Piping located under a floor slab. <br /> .Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower door test shall be provided before C.O: <br /> 26.A copy of the energy cacls shall be with permit at all times <br /> 27. Copu of final insulddowreport shall be pr®vided with permit before rinal <br /> 28. No fence,pool or screen enclosure Is issued with this permit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />